Download Print this page
Extech Instruments WTH600-E User Manual

Extech Instruments WTH600-E User Manual

Wireless weather station with wireless transmitter sensor

Advertisement

Quick Links

1.800.561.8187
WTH600-E WIRELESS WEATHER STATION
WITH WIRELESS TRANSMITTER SENSOR
FOR USE IN EU and UK ONLY
WTH600-E
1. INTRODUCTION
Thank you for selecting the Extech WTH600-E Wireless Weather Station with 5-in-1 wireless
sensor. The sensor includes a self-emptying rain collector for measuring rainfall, an anemometer
for wind velocity, a wind vane for wind direction, a temperature sensor, and a relative humidity
sensor. The WTH600-E comes fully assembled and calibrated for convenience. The sensor transmits
data up to 492 ft. (150m), line of sight, to the main display unit via low power radio frequency. The
main unit displays all of the weather data received from the sensor and the user can recall stored
weather data (24-periods). Includes Radio Controlled Clock feature (MSF/DCF). The WTH600-E is a
powerful and unique personal weather station that, with proper use, will provide years of reliable
service.
FEATURES
Radio Controlled Clock (MSF/DCF)
HI/LO Alarms alert the user when programmed weather limits are exceeded
Barometric pressure is computed and helps forecast the weather and possible storms
Min/Max feature includes date/time stamp
View Rainfall rate and daily/weekly/monthly amounts
Wind-speed levels are shown expressed in Beaufort scale
Wind-chill, Heat Index, Dew point, and Comfort level are computed and displayed
www.
USER MANUAL
WTH600-E
information@itm.com
.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the WTH600-E and is the answer not in the manual?

Questions and answers

Summary of Contents for Extech Instruments WTH600-E

  • Page 1 WTH600-E 1. INTRODUCTION Thank you for selecting the Extech WTH600-E Wireless Weather Station with 5-in-1 wireless sensor. The sensor includes a self-emptying rain collector for measuring rainfall, an anemometer for wind velocity, a wind vane for wind direction, a temperature sensor, and a relative humidity sensor.
  • Page 2 MAXIMUM / MINIMUM MEMORY HI / LO WEATHER ALERT WIRELESS SIGNAL RECEPTION TEMPERATURE/HUMIDITY COMFORT LEVELS CLEARING STRAY READINGS POINTING SENSOR TO THE SOUTH MOON PHASES CLEANING TROUBLESHOOTING PRECAUTIONS FCC STATEMENT Error! Bookmark not defined. SPECIFICATIONS EU/UK Version WTH600-E-en-GB_v1.0 4/18 1.800.561.8187 information@itm.com www. .com...
  • Page 3 1.800.561.8187 information@itm.com www. .com...
  • Page 4 1.800.561.8187 information@itm.com www. .com...
  • Page 5 8. Day of the week 9. Alarm icon 10. Date 11. Month Indoor Temperature/Humidity Display 1. Comfort/cold/hot icon 2. Indoor indicator 3. Indoor humidity 4. Hi / Lo Alert and Alarm 5. Indoor temperature EU/UK Version WTH600-E-en-GB_v1.0 4/18 1.800.561.8187 information@itm.com www. .com...
  • Page 6 6. Hourly records indicator Rainfall Display 1. Rainfall indicator 2. Time range record indicator 3. Day records indicator 4. Histogram 5. Hi Alert and Alarm 6. Current rainfall rate 7. Rainfall unit (in / mm) EU/UK Version WTH600-E-en-GB_v1.0 4/18 1.800.561.8187 information@itm.com www. .com...
  • Page 7 Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment. EU/UK Version WTH600-E-en-GB_v1.0 4/18 1.800.561.8187 information@itm.com www.
  • Page 8 The included leveling device ensures a level installation. 4. Mount the wireless sensor with the wind meter end pointing to the North. 5. Pole mount shown below left and railing mount below right. EU/UK Version WTH600-E-en-GB_v1.0 4/18 1.800.561.8187 information@itm.com www.
  • Page 9 5. MAIN UNIT OPERATION, BATTERIES, MOUNTING Battery Installation and Mounting The WTH600-E can be placed on a desktop or can be wall mounted for easy viewing. 1. Remove the battery door of the main unit. ity marks on the battery compartment.
  • Page 10 Permanent Disable / Enable RCC Signal Reception 1. Press and hold [RCC] button for 8 seconds to disable the reception permanently. 2. Press and hold [RCC] button for 8 seconds to enable automatic RCC reception. EU/UK Version WTH600-E-en-GB_v1.0 4/18 1.800.561.8187 information@itm.com www.
  • Page 11 (alarm will sound 30 minutes earlier if it detects outside temperature is below 26°F (-3°C)). 6. WEATHER FORECAST The WTH600-E includes a sensitive pressure sensor that predicts weather for the next 12 ~ 24 hours within a 19-31 miles (30 to 50km) radius. Note: 1.
  • Page 12 1. Press and hold [RAINFALL] button 2 seconds to enter unit setting mode. 2. Use [UP] [DOWN] buttons to toggle between mm (millimeter) and in (inch). 3. Press [RAINFALL] button to confirm and exit. EU/UK Version WTH600-E-en-GB_v1.0 4/18 1.800.561.8187 information@itm.com www.
  • Page 13 Wind felt on exposed skin. Leaves rustle. Wind vanes begin to move. 4 7 mph 4 6 knots 1.6 3.4 m/s Gentle breeze 12 19 km/h Leaves and small twigs constantly moving, light flags EU/UK Version WTH600-E-en-GB_v1.0 4/18 1.800.561.8187 information@itm.com www. .com...
  • Page 14 Note: The wind chill factor is based on the combined effects of temperature and wind speed. The wind chill displayed is calculated solely from temperature and humidity measured by the wireless sensor. EU/UK Version WTH600-E-en-GB_v1.0 4/18 1.800.561.8187 information@itm.com www. .com...
  • Page 15 MAX average gust MAX gust Max rainfall Press and hold [MAX/MIN] for 2 seconds to reset the MAX/MIN records. Note: The display shows date/time stamp along with all maximum or minimum readings. EU/UK Version WTH600-E-en-GB_v1.0 4/18 1.800.561.8187 information@itm.com www. .com...
  • Page 16 14. HI / LO WEATHER ALERT The WTH600-E can alert you to specific weather conditions. When the alert function is active, the amber LED flashes when certain conditions exist; see table below. Area Types of Alerts Available Indoor Temperature HI and LO alert...
  • Page 17 3. Use [UP] / [DOWN] buttons to move to the lower part (Southern Hemisphere). 4. Press the [WIND] button to confirm and exit. Note: Changing hemispheres will automatically switch the direction of the displayed moon phases. EU/UK Version WTH600-E-en-GB_v1.0 4/18 1.800.561.8187 information@itm.com www.
  • Page 18 3. Remove carefully any dirt or insects inside the sensor casing (Do not let the sensors inside get wet). 4. Clean the shield with water and remove any dirt. 5. Re-assemble after fully cleaning and drying. EU/UK Version WTH600-E-en-GB_v1.0 4/18 1.800.561.8187 information@itm.com www. .com...
  • Page 19 Sunny / Clear, slightly Cloudy, Cloudy, Rainy, Rainy / Stormy and Snowy Display modes Current, Max, Min, Historical data for last 24hrs Memory modes Max & Min from last memory reset (with time stamp) INDOOR TEMPERATURE EU/UK Version WTH600-E-en-GB_v1.0 4/18 1.800.561.8187 information@itm.com www. .com...
  • Page 20 +/- 7% or 1 tip (whichever is greater) Display modes Rainfall (Rate / Daily / Weekly / Monthly), Historical data for past 24 hours Memory modes Total rainfall from last memory reset EU/UK Version WTH600-E-en-GB_v1.0 4/18 1.800.561.8187 information@itm.com www. .com...
  • Page 21 Heat Index range 26~50°C (78.8~122°F) Indoor Dew Point range -40~70°C (-40~158°F) Copyright © 2018 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form EU/UK Version WTH600-E-en-GB_v1.0 4/18 1.800.561.8187 information@itm.com www. .com...