Air regulator, filter, lubricator range

Advertisement

3.
CONTENT & INSTALLATION
3.1.
Confirm that all items are present and undamaged. If any parts are missing or damaged please contact the supplier.
SA106 - Combined filter, regulator with gauge, lubricator and mounting bracket.
SA106FR - Combined filter, regulator with gauge and mounting bracket.
SA106F - Filter.
SA106L - Lubricator.
SA106R - Regulator with gauge and mounting bracket.
3.2.
Fig.1 shows a typical air line installation. The filter is located
upstream of the regulator - unless combined, as in SA106
and SA106FR - and the lubricator downstream.
3.3.
Filter/regulator - Install using the mounting bracket provided.
Before connecting system piping ensure that gauge is visible,
unused gauge port is sealed with plug provided and that flow
direction arrow matches system air flow.
3.4.
Filter and Lubricator - Install into air piping or connect directly to bracket mounted regulator using fittings provided. Always check that
flow arrows are correct and that filter is upstream, and lubricator downstream, of regulator.
Note: To ensure air-tight joints, use PTFE tape.
4.
OPERATION
4.1.
Regulator - The output pressure is controlled by the knob. Before pressurising the air system
for the first time, pull out and rotate the knob anticlockwise to remove any loading on the
regulator spring. Pressurise the system and then rotate knob clockwise to set required output
pressure, as shown on gauge. When the required pressure is achieved push in knob to prevent
inadvertent adjustment.
Note: For correct pressure setting always adjust up from a lower pressure. Therefore to
reset from 90 to 70psi for example, reduce pressure from 90 to 60psi and then increase to 70psi.
4.2.
Filter - The bowl should be drained regularly to prevent an excessive build-up of water/oil. Pull down
the drain valve at the bottom of the bowl, allow to drain and then release. Drain valve has
female 1/8" BSP outlet.
4.3.
Lubricator - Remove the filler plug (fig.2.A) and fill bowl up to max. level, with air tool oil.
This can be done with the air line pressurised. With air flowing through the lubricator the oil
delivery rate can be adjusted by screw (fig.2.C) whilst watching the drip rate through the sight
dome (fig.2.B). The oil delivery rate will automatically increase or decrease in line with the air flow.
4.4.
Both the filter and the lubricator are supplied with a metal bowl guard. To remove the guard, pull
down the latch (fig.3.D) and rotate the guard until either of the two pairs of lines (fig.3.E) on
the guard align with the similar marks (fig.3.F) on the head. The guard can now be removed.
To refit, slide the top of the guard into the head with the guard and head markings aligned,
and then rotate the guard so that the latch aligns with the marks on the head. The latch will
lock into place.
5.
PARTS
MODEL:
SA106
Filter Bowl:
SA106.B
Lubricator Bowl:
SA106.B1 ---
Regulator gauge: SA106.G
Plastic Ring:
SA106.PR SA106.PR
Wall Bracket:
SA106.WB SA106.WB1 ---
The following fittings are also available from your supplier:
SA1/1214F . .1/2"BSP male -1/4"BSP female reducer
SA1/3814F . .3/8"BSP male -1/4"BSP female reducer
SA1/1414 . . .1/4"BSP male -1/4"BSP male connector
6.
DECLARATION OF CONFORMITY
Declaration of Conformity
Air Regulator, Filter & Lubricator Range
Models: SA106, SA106FR, SA106F,
SA106L & SA106R
97/23/EC Pressure Equipment Directive
98/37/EC Machinery Directive
93/68/EEC Marking Directive
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our catalogue and latest promotions call us on 01284 757525 and leave your full name, address and postcode.
SA106FR
SA106F
SA106L
SA106.B
SA106.B ---
---
SA106.B1 ---
SA106.G
---
---
---
---
---
We, the sole importer into the UK, declare that the products listed here are in conformity with the following standards and directives.
The construction files for these products are held by the Manufacturer and may be inspected, by a national authority, upon
request to Jack Sealey Ltd.
Signed by Mark Sweetman
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
fig.1
SA106R
---
SA106.G
SA106.PR
SA106.WB1
Date: 12th April 2006
01284 757500
01284 703534
fig.2
fig.3
www.sealey.co.uk
Web
sales@sealey.co.uk
email
SA106/106FR/106F/106L/106R - 1 - 120406

Advertisement

loading

This manual is also suitable for:

Power products sa106frPower products sa106fPower products sa106lPower products sa106r