Williams Medi+ LWMP620 Operating Manual page 11

Natural refrigerant cabinets
Table of Contents

Advertisement

CONDENSER CLEANING
Regular maintenance should be carried out on a
regular basis by competent / trained personnel. The
condenser is part of the refrigeration unit and is
located in the unit compartment.
Brush fins vertically with a stiff brush, taking care
not to damage them or to push dirt / dust further in,
and then vacuum away.
FIG 3.
TOP MOUNTED CABINETS
(WMP620 - WMP1295)
The condensing unit and refrigeration equipment
can be accessed from above or in some cases
behind. Remove fixings in the top and bottom edges
of the unit cover and pull the unit cover away from
the cabinet and retaining clips.
BOTTOM MOUNTED UNITS
(WMP523)
Pull the unit cover away from the cabinet and
retaining clips.
CLEANING / REPLACING THE GASKET
Door gaskets should be checked and cleaned
regularly and replaced if damaged. To clean the
gasket, wipe with warm soapy water and a soft cloth,
ensuring it is completely dry before closing the door.
DO NOT use a sharp knife to clean or scrape the
gasket. Damaged gaskets do not seal correctly and
can increase the amount of electricity consumed,
seriously affecting the efficiency and performance of
the appliance.
Damaged gaskets are easily
replaced. Simply pull out the
existing part and push the new
gasket into the channel (gasket
retainer) at the centre and work
along, pushing gasket into
channel.
EVAPORATOR/DRAINLINE
Inspect periodically to ensure the drain hole is not
blocked.
APPLIANCE ROUTINE MAINTENANCE / CLEANING
BREAKDOWN
In the event of a breakdown, please contact Williams
Refrigeration or your Service Provider
When calling, please advise model and serial
number. This information can be found on the data
plate inside the appliance. Please ensure that all
redundant parts are disposed of safely and legally.