M4 flat head screw X 4pcs APS15-3A host 3 in 1 power cord Baffle plate M3 flat-head screws X 3pcs Spray nozzles X 4pcs Fixed cover ESD ground wire X 2pcs MS-300 Manual hot air gun holder connection plate Certificate of qualification...
Page 4
MS-300 Assemble diagram Baffle plate Install the baffle plate to the fixed cover, and install the Fixed cover plastic thumbscrews. 2 Connection plate is aligned with the screw hole at the connection plate lower part of the fixing cover, and install the M4 flat head screw.
ST-862DHot Air Station User Manual Schematic Diagram of the Whole Equipment ST-862D Shortcut Key 1/ Menu Key/ Menu Turn-up Key Temp Plus Key Blowing Plus Key Blowing Minus Key Temp Minus Key Shortcut Key 2/ Shortcut Key 1/ Menu Key/ Menu Exit Key Menu Turn-down Key Hot Air Handle...
Technical Data Model: ST-862D Voltage AC230V±10% 50Hz (110V±10% 60Hz Optional) Power 1000W Fuse type T6.3A T12A Temperature range: ±35℃ Temperature accuracy Temperature unit °C/°F (default °C) Air flow 20~120L/min Standby heater Support cooling function Heating element remove detection; heating element open Abnormal detection of circuit detection;...
Boot-up Screen After the station has been switched on, the display will turn on and show the system version number for one second before switching to the normal display. (Means ST-862D V0.1 version) Settings 1. Normal display (FIG. 1-1) shows real temperature is 300°C, the temperature setting value is locked, the air volume is 50% and the heating power value is 3 bars.
Page 8
Temperature/Air Flow Setting 1. Adjust the air volume: Press air “▲” or “▼” key (see FIG 1-4). Long press for quickly adjusting. Stop pressing the key for 3 seconds, it will save the setting automatically. 2. Adjust temperature value (when temperature value is locked, it can not be adjusted): Press temperature "▲"...
Menu Mode Enter into menu mode by pressing both Button “1” and “3” more than 3 seconds under working status. 1. Button Definition under Menu Setting Mode Button “1”: Menu page up Button “2”: Menu exit Button “3”: Menu page down Parameter plus Parameter minus FIG.
Page 10
4. Restore Factory Setting In FAC menu ,press “▲”and“▼”keys to adjust ON/OFF. Press the [2] key when the menu is ON, then return to the normal operation interface to restore factory setting 0 F F REAL REAL F A C F A C FIG.
Page 11
6. Button Beeping Function Under menu BL mode, user can turn on/ off the beeping function by pressing “▲”or “▼”key.Refer Pic.1-16, OFF disable beeping function;Refer Pic.1-17, ON enables beeping function. O F F REAL REAL FIG. 1-16 FIG. 1-17 7. Defining Work Function Under menu HTO mode, it can adjust time of defining work by pressing “▲”or“▼”...
Page 17
Note: User need calibrate temperature by adjusting its value if the displayed temperature is much different with actual-measured temperature after changing a new heater or tips, its calibration method be refered as below: 1.Set this handle required calibration as a suitable temperature like 350℃/ 662℉; 2.After this setting temperature is stable, use temperature tester to measure the actual temperature of its tip, for example, its actual-measured temperature is 365℃/ 689℉;...
User Manual of APS15-3A Maintenance Power Supply Product Introduction APS series power supply is designed for the needs of electronic training schools, communication maintenance technicians and related engineering research and development personnel. The current best-stability series voltage stabilization scheme is adopted for this product, and the digital MCU chip is used for control.
Technical Parameters Constant Voltage mode (CV): Output voltage range: 0 to rated voltage continuously adjustable. Power supply variation rate: ≤ 0.01%+3mV. Load variation rate: ≤ 0.01%+3mV (rated current ≤ 3A). Recovery time: ≤ 120 μs (50% load variation, minimum load of 0.5A). Ripple and noise: ≤...
Page 22
Operating Instructions 1. Precautions before use AC power input: AC power input shall be within the range of rated voltage ±10% 50/60hz. Warning: the protective conductor of the power line must be earthed to avoid electric shock. Instrument installation: Avoid using this power supply in the environment above 40℃. Reserve enough space for heat emission holes on the rear panel to dissipate heat.