Unipower PCM500 Series Operating Manual

Power control & monitor system

Advertisement

Quick Links

DESCRIPTION
UNIPOWER Telecom's PCM500 Series
Power Control and Monitor System
(PCMS) is a one mounting position high
(1.75 inches) basic control and monitoring
system for DC power plants. It controls up
to 16 rectifiers in up to 4 shelves, precisely
setting the float voltage and equalize
voltage (optional) on all rectifiers
simultaneously. It monitors the battery
voltage and current by means of front
panel test points or optionally by a front
panel digital voltmeter and ammeter.
A front panel yellow LED indicates that the
controller is in the optional equalize voltage
mode. Front panel red LEDs give the following
alarms: rectifier fail alarm-minor, indicating a
single rectifier failure; rectifier fail alarm-major,
indicating two or more rectifier failures; AC input
failure on any rectifier; failure on any fuse or
circuit breaker; failure on one or both low voltage
disconnects; battery overvoltage; and battery
undervoltage. These alarms all have isolated
Form C relay contact outputs.
The PCM500 is available in either 48 or 24VDC
versions and will operate with a positive or
negative polarity plant. It comes with brackets
that permit mounting in either a 19- or 23-inch
relay rack and can be mounted from the front of
the rack with offsets every quarter-inch from
front to back to align with exisitng rack-mounted
equipment. The front panel has voltage adjust-
ment potentiometers for float voltage, equalize
voltage (option), battery overvoltage and
undervoltage, and temperature compensation
set (option). A front panel switch puts the PCMS
in either float or equalize voltage mode. A front
panel green/red LED indicates the controller is
operating or has failed. The PCMS 500 mates
with UNIPOWER Telecom's rectifiers and
shelves.
SAFETY CERTIFICATIONS
UL1950
CSA 22.2, No. 950
EN60-950
TWO-YEAR WARRANTY
www.unipowertelecom.com
954-346-2442
PCM500 SERIES
POWER CONTROL & MONITOR SYSTEM
POWER CONTROL & MONITOR SYSTEM
MODEL
PCM500
Basic Power Controller
FEATURES
¿ One Mounting Position High: 1.75"
¿ 19- or 23-Inch Rack Mounting
¿ Positive or Negative Polarity Plant
¿ Reverse Polarity Protected
¿ 48 or 24VDC Versions
¿ Controls & Monitors Up to 16 Rectifiers
¿ Centralized Plant Float Voltage Adjust
¿ Centralized Plant Equalize Voltage Adjust Option
¿ Battery Temp. Compensation Option
¿ Optional Digital Voltmeter and Ammeter Panel
¿ 8 LED Alarm Indicators
¿ 8 Form C Relay Contact Alarm Outputs
¿ Over & Under Battery Voltage Alarms
¿ Battery Voltage & Current Test Points
¿ Compatible with Mercury & Vanguard Rectifiers
¿ Easy Wire Connections on Rear
¿ Alarm Enable on Back Panel
LVD73/23/EEC
FUNCTION

Advertisement

Table of Contents
loading

Summary of Contents for Unipower PCM500 Series

  • Page 1 PCM500 SERIES POWER CONTROL & MONITOR SYSTEM DESCRIPTION UNIPOWER Telecom’s PCM500 Series Power Control and Monitor System (PCMS) is a one mounting position high (1.75 inches) basic control and monitoring system for DC power plants. It controls up to 16 rectifiers in up to 4 shelves, precisely...
  • Page 2 DIV. OF UNIPOWER CORP. • 3900 Coral Ridge Drive, Coral Springs, Florida 33065, UNITED STATES • Tel: 954-346-2442 • Fax: 954-340-7901 • sales@unipower-corp.com UNIPOWER EUROPE • Parkland Business Centre, Chartwell Road, Lancing, BN15 8UE, ENGLAND • Tel: +44(0)1903 768200 • Fax: +44(0)1903 764540 • info@unipower-europe.com...
  • Page 4 UNIPOWER Telecom, Division of UNIPOWER Corporation NORTH AMERICA • 3900 Coral Ridge Drive, Coral Springs, Florida 33065, USA • Tel: +1 954-346-2442 • Fax: +1 954-340-7901 • sales@unipower-corp.com EUROPE • Parkland Business Centre, Chartwell Road, Lancing BN15 8UE, ENGLAND • Tel: +44(0)1903 768200 • Fax: +44(0)1903 764540 • info@unipower-europe.com...
  • Page 5: Table Of Contents

    CONTENTS SECTION TOPIC PAGE Introduction Features and Options Safety Warnings Warranty Unpacking and Inspection Specifications Safety and Industry Standards Front Panel Description Back Panel Description 10.0 LED Indicators 11.0 Front Panel Adjustment Potentiometers 12.0 Description of Operation 13.0 Connections 14.0 Alarm Enabling 15.0 Voltage and Current Measurements...
  • Page 6 ILLUSTRATIONS FIGURE TITLE PAGE PCM500 Power Control & Monitoring System Front and Back Panels of PCM500 PCM500 Functions Current Measurement Connections Test Setup for Setting Battery Overvoltage and Undervoltage...
  • Page 7: Introduction

    PCM500 SERIES OPERATING MANUAL UNIPOWER TELECOM POWER CONTROL & MONITOR SYSTEM PCM500 SERIES INTRODUCTION This Operating Manual should be read through carefully before installing and operating the PCM500 Series. The PCM500 is a basic control and monitoring system for DC power plants.
  • Page 8 PCM500 SERIES OPERATING MANUAL Figure 1. PCM500 Power Control & Monitoring System FRONT VIEW ALARM-ENABLE RECTIFIER SHELF CONNECTORS TB1 CONNECTOR DIP SWITCHES REAR VIEW Figure 2. Front and Back Panels of PCM500...
  • Page 9: Safety Warnings

    All products returned for repair must be shipped freight prepaid to UNIPOWER. If the buyer fails to fully comply with the foregoing, the buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property or any other incidental or consequential losses) shall be available to the buyer.
  • Page 10: Unpacking And Inspection

    Also save the shipping carton and packing material as evidence of damage for the freight carrier’s inspection. UNIPOWER Telecom will cooperate fully in case of any shipping damage investigation. Always save the packing materials for later use in shipping the unit. Never ship the rectifier system without proper packing.
  • Page 11: Safety And Industry Standards

    PCM500 SERIES OPERATING MANUAL ENVIRONMENTAL Operating Temperature Range ....0°C to 50°C Storage Temperature Range ....-40°C to +85°C Humidity ........0% to 95%, Non-Condensing PHYSICAL SPECIFICATIONS Case Material ..........Steel Finish ............. Powder Coat Gray Dimensions, Inches (mm) ....... 1.75 H x 19.00 W x 9.00 D (44.5 x 483 x 229)
  • Page 12: Back Panel Description

    PCM500 SERIES OPERATING MANUAL float voltages. Finally, in order, are the LED indicators: RFA-MIN, RFA-MAJ, ACFA, FA, LVDA, OVA and UVA which are explained in Section 10.0. BACK PANEL DESCRIPTION From the left side are the four rectifier connectors J1 through J4 which con- trol and monitor the rectifier shelves and individual rectifiers.
  • Page 13: Description Of Operation

    (Positronic No. SD25F0S500X with FC7520D pins). The mating plug is a Positronic SD25M0000Z with MC7520D pins. These connectors are identical to and automatically mate with those on all UNIPOWER Telecom rectifier shelves: Mercury (RMF), Magellan (RMM, RMP), Vanguard (RVN) and Ranger (RRS).
  • Page 14 FUSE/CIRCUIT RECTIFIER BREAKER PANELS SHELVES Figure 3. PCM500 Functions...
  • Page 15 PCM500 SERIES OPERATING MANUAL J1-J4 SIGNAL CONNECTORS FUNCTION PIN FUNCTION AC Good-1 DC Good-1 AC Good-2 DC Good-2 J1-J4 AC Good-3 DC Good-3 AC Good-4 DC Good-4 Signal Common Current Share -Sense + Sense Remote Adjust-1 Remote Adjust-2 Remote Adjust-3...
  • Page 16 PCM500 SERIES OPERATING MANUAL Outputs on terminals 13-36 are Form C relay contact alarms for the functions given. “Normally Closed” (NC) means a “short” between this terminal and the Common (C) terminal when the function is operating properly with power applied.
  • Page 17: Alarm Enabling

    PCM500 SERIES OPERATING MANUAL circuitry. 13.44 CS Output. This is the current share connection to the four rectifier shelves and is used only if additional rectifier shelves are added to the system. 13.45 BS+ and BS- Inputs. These are battery sense inputs to PCM500 and are connected to the common rectifier bus near the battery but on the rectifier side of any battery disconnect or LVD circuit.
  • Page 18: Voltage And Current Measurements

    PCM500 SERIES OPERATING MANUAL ALARM-ENABLE DIP SWITCHES POS. SW. NO.1 SW. NO.2 SW. NO.3 SW. NO.4 FUNCTION FUNCTION FUNCTION FUNCTION SR11 SR21 SR31 SR41 SR12 SR22 SR32 SR42 SR13 SR23 SR33 SR43 SR14 SR24 SR34 SR44 LVDA1 LVDA2 The FA1 through FA5 alarms function for up to five fuse or circuit breaker distribution panels.
  • Page 19 PCM500 SERIES OPERATING MANUAL Figure 4. Current Measurement Connections Figure 5. Test Setup for Setting Battery Overvoltage and Undervoltage...
  • Page 20: Battery Temperature Compensation

    PCM500 SERIES OPERATING MANUAL This table shows that, for example, a 50mV, 100A shunt is the shunt resis- tance that produces 50mV for a 100A full-scale current. In this case the shunt resistance is 50mV ÷ 100, or 0.5 milliohm. The shunt rating is always the full-scale current that produces 50mV across the shunt.
  • Page 21: Installation And Setup

    PCM500 SERIES OPERATING MANUAL 17.0 INSTALLATION AND SETUP 17.1 Mounting. The PCM500 can be mounted in either 19- or 23-inch racks by using the appropriate brackets. Mount it from the front of the rack using the correct offsets to align with existing rack-mounted equipment. The bracket offsets are every quarter-inch from front to back.
  • Page 22: Final Installation And Connections

    Connect the rectifier shelves to be used to the J1 to J4 connectors on the back of the PCM500. Use up the positions in sequence, one through four. Likewise, fill the shelves with rectifiers in sequence, leaving any blanks at the end of the sequence. All UNIPOWER Telecom rectifier connections are...
  • Page 23 OPERATING MANUAL compatible with the PCM500 J1-J4 connectors. Compatible cables are available from UNIPOWER Telecom; contact the factory. If another manufacturer’s rectifiers and shelves are used, they must be properly con- nected, pin for pin, to be compatible with J1-J4 as shown in the “Signal Connectors”...
  • Page 24 PCM500 SERIES OPERATING MANUAL 18.9 Connect the BS+ and BS- (battery sense) inputs to (TB1 terminals 39 and 38 respectively) to the positive and negative sides of the battery, but on the rectifier side of any battery disconnects or circuit breakers.

Table of Contents