INSTALL HOOD

Hang hood from (4) Mounting Screws (from parts bag).
1
Slide hood towards wall until mounting screws are engaged
in narrow end of (4) Keyholes. Tighten mounting screws
securely.
CAUTION
DO NOT PUSH ON FAN BLADE. Pushing on the
blade may cause it to interfere with other hood parts.
Connect ductwork to hood. Use Duct Tape to make joints
2
secure and air tight.
Install (2) PAR20, 50 W Maximum Halogen Bulbs or (2)
3
R16, 40 W Maximum Incandescent Bulbs. Purchase bulbs
separately.
!
CAUTION:
Bulbs may be hot! Refer to bulb packaging
for further information.
4
Replace filters and make sure fan blade turns freely. Turn on
power at service panel, and test for proper operation.
NON-DUCTED FILTERS
If hood is to be installed Non-Ducted:
Purchase a set of (2) non-ducted filters from your local distributor or
retailer and attach them to the aluminum mesh filters.
OPERATION
KEYHOLE
(4)
MOUNTING
SCREW
(4)
Fan: The 3-position rocker switch (on the left) controls the fan. The
left position is low speed, center position is off, and right position is
high speed. An indicator light shows that the fan is on.
Light: The 3-position rocker switch (on the right) controls the lights.
The left position is low light intensity, center position is off, and right
position is high light intensity.
DUCT
TAPE
CLEANING
Aluminum mesh filters: Clean frequently using hot water and a
mild detergent. Filters are dishwasher safe.
Charcoal filters: Clean filter surfaces frequently with a damp cloth
and a mild detergent. DO NOT immerse filters in water or put in
dishwasher. The special "Clean Sense" feature indicates when the
filter is to be replaced. The blue and yellow strips will blend to green
PAR20,
when it is time to change the filter. The "Clean Sense" feature works
50W MAX.
best when facing toward the cooking surface.
HALOGEN
To clean hood: Remove filters. Use a damp cloth and a mild deter-
BULB (2)
gent to wipe all grease-laden surfaces. Use care when cleaning fan
- or -
blade - it must not become bent or misaligned. DO NOT ALLOW
R16,
WATER TO ENTER MOTOR. Make sure all surfaces are completely
40W MAX.
dry before re-installing filters and restoring power.
INCANDESCENT
Motor is permanently lubricated. Do not oil or disassemble motor.
BULB (2)