General Description; Safety Instructions; Technical Information; Fluid Compatibility - FILL-RITE 305RU Owner's Operation & Safety Manual

Remote dispenser
Table of Contents

Advertisement

Dear Fill-Rite Customer,
Thank you for buying a Fill-Rite product. We believe that you
have bought the best. This piece of literature contains
information about your new equipment and its operating and
service requirements. Please take a few minutes to read it
carefully.
Fill-Rite's products are distributed around the world and are
the result of people at Fill-Rite working together to design,
manufacture, sell, ship and service products which meet the
needs of each and every customer.
If, for any reason, any of our products do not meet your
performance expectations, we would like to hear from you.
Our best sales force is you, our customer, and we want you to
be satisfied. We appreciate your purchase of a Fill-Rite
product and look forward to providing your future equipment
needs.
Sincerely,
George P. Jenkins
President

SAFETY INSTRUCTIONS

1. DO NOT smoke near dispenser or use dispenser
near an open flame when pumping flammable
fluids. Fire could result. Installation should be in
accordance with NFPA 30A.
2. Dispenser should be properly grounded and rigid
conduit should be used when installing electrical
wiring.
3. Use gasoline resistant compound on threaded
joints.
4. This product should not be used for fluid transfer
into aircraft.
5. This product is not suited for use with fluids for
human consumption or fluids containing water.
6. A filter should be used on dispenser outlet to ensure
that no foreign material is transferred to fuel tank.
DANGER
Electrical wiring should be
done by a licensed electrician
in accordance with NFPA 30A
and 70. Improper use or instal-
lation of this product can
cause serious bodily injury or
death.

GENERAL DESCRIPTION

The 305 Remote Dispenser is a power operated petroleum
dispensing device, for use on fixed aboveground tanks with a
maximum capacity in accordance with NFPA 30A. It is used
in conjunction with a tank top pump and can handle a variety
of fuels up to 40 GPM at ±2% accuracy.
The dispenser can operate with a 110V/60Hz or 220V/60Hz
pump, if desired. The 305 is equipped with a Fill-Rite 900
Series Meter with a manual reset (for non-resale applications).
The 900 Meter is accurate at ±2% in a flow range from 6 to 40
GPM.

TECHNICAL INFORMATION

Design Features
•1" NPT inlet, 1" NPT outlet
•50 PSI maximum pressure
•Furnished with 12' hose and manual nozzle
•Meter:
•Positive displacement, nutating disc type
•Can be calibrated for ±2% accuracy within a fluid
range of 6 to 40 GPM (23 to 151 LPM)
•Register:
•Three resettable unit wheels with large 11/16"
figures and tenths wheel
•Totalizer reads to 999,999.9 gallons
•Cabinet measures 13"W x 11 1/2"D x 10 1/2"H
•Liter measure:
•Four resettable unit wheels
•Totalizer reads to 99,999,999 liters
•Front or rear discharge
•Red or white cabinet
•Universal nozzle boot for automatic or vapor recovery
nozzles
•Automatic nozzle for standard or universal boot
•High flow automatic nozzle for universal boot
•Filter kits
•Tank mounting bracket

Fluid Compatibility

If in doubt about compatibility of a specific fluid, contact
supplier of fluid to check for any adverse reactions to the
following wetted materials.
Steel
Polyester
Fluorocarbon
Buna N
2
OPTIONS
Aluminum
300S Stainless Steel

Advertisement

Table of Contents
loading

Table of Contents