THERMOSTATIC DHW RECIRCULATION KIT
This thermostatic recirculation kit for DHW mixers is supplied separately from the mixer itself. The kit consists of a pump
with a non-return valve and shut-off cock, pipe, seals and a safety valve.
Description
- Recirculation pump with packing
- Instruction manual
GENERAL SAFETY INFORMATION AND PRECAUTIONS
READ THE MANUAL SUPPLIED WITH THE DHW MIXER THOROUGHLY BEFORE PERFORMING ANY WORK ON IT.
1 Pump
2 Pipe with seals
3 Safety valve
Flow rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 m
Head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 m
Pumped water temperature . . . . . . . . . . . . . . . . .2 ÷ 65 °C
Maximum pressure. . . . . . . . . . . . . . . . . . . . . . . .10 bar
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . .200-240 V
Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50-60 Hz
Index of protection . . . . . . . . . . . . . . . . . . . . . . .IP 44
DESCRIPTION
CONTENTS OF KIT