Ketotek KT4000 Operating Manual

Temperature controller

Advertisement

KT4000 Temperature Controller

1. Overview

KT4000 is easy-to-use and reliable dual relay output
temperature controller. It can be used as automatic
temperature control system for various electric appliances.

2. Mail Features

Acrylic panel, plastic-steel socket shell
Control heater and cooler to adjust temperature.
One setpoint and one differential .Very easy to set .
Alarm when temp exceed temperature limit or sensor error
Autosave the program setting when power down.

2. Specifications

Power Supply: 110Vac±15% , 50/60hz
Temperature control range:-19.9~199.9℉
Return difference :1.0~30℉
Temperature control accuracy: ±1℉
Screen resolution : 0.1℉
Temperature sensor : NTC Waterproof sensor 2m/6.56ft
Output Relay Contact Capacity: 16A, 100-240Vac

3. Product picture

Left heating socket connect with heater.
Right cooling socket connect with refrigerator/cooler.
Dimensions:
Control panel: 92x50x17mm (3.6x1.97x0.67inch)
Socket: 208x66x40mm (8.2x2.6x1.57inch)

4. Key Instruction

Ketotek Technology Inc.
Operating Manual
: Cool output indicator. When this light on, cooling
socket have power output. Cooler start to work ; When the
light flash, cooling socket output delay .
:
Heat output indicator. When this light on, heating
socket have power output. Heater start to work.
:
Temperature alarm.When the temperature exceed the
limit range of AL~AH, this light flash and buzzer alarm.

Operation

In normal working status, the screen display RT(real time
temperature detected from sensor). press
temperature set value LS(see code table). press
display differential value Ld.
The screen backlight will closed after 10minutes
no-operation.
In normal working status, press SET for 3s to enter setting
parameter mode. The screen display LS. Press
increase or decrease LS value. Then press SET to go into
next code Ld. Press
Using the same way to set code value from LS~CA one by
one (see code table). After finishing all setting, press SET
for 3seconds to save the setting and return to normal
display. If no key operation after finishing all settings
within 30seconds, the system won't save modified
parameter and back to normal display.
Restore factory default setting:
In normal working status, press
The screen will display FF and restore all code to default
factory setting.
Code Table:
Code
Function
LS
Temperature Set Value
Ld
Differential Value
PL
Set cooling delay output
AH
Alarm high limit
AL
Alarm low limit
CA
Temperature Calibration
Basic setting
For example,we use this thermostat to control temperature
of a reptile incubator. Heating socket connect with
light.Cooling socket connect with fan.
Only need to set LS=80 ℉ . No need to change other
parameters.
►Fan works when temperature≥84℉. Fan stop working
when temperature <80℉.
►Light works when temperature<76 ℉ . Light stop
working When temperature≥80℉.
Advanced Setting.
Set the required temperature LS. Then set Ld PL AH AL
CA. (AH>LS+Ld , AL<LS-Ld). The controller will work
in following status:
1
once. it display
or
to adjust value.
and
together for 3s.
Set Range
-19.9~199.9℉ 68℉
1.0~30℉
0~10minutes
-19.9~199.9℉ 199.9℉
-19.9~199.9℉ -19.9℉
-19.9~19.9℉
www.cnketotek.com
once. it
or
to
Default
4℉
0
0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KT4000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ketotek KT4000

  • Page 1 • Temperature alarm.When the temperature exceed the • KT4000 is easy-to-use and reliable dual relay output limit range of AL~AH, this light flash and buzzer alarm. temperature controller. It can be used as automatic temperature control system for various electric appliances.
  • Page 2 • Temperature Calibration CA • When there is deviation between measured temperature and actual temperature, we can set CA value to align measured temperature and actual temperature. The corrected temperature = measured temperature + CA Ketotek Technology Inc. www.cnketotek.com...

Table of Contents