of the model selected will be dropped to the appropriate Channel Port. Common
Port Left drops and adds wavelength traffic from Channel Port Left and Common
Port Right drops and adds wavelength traffic from Channel Port Right.
Installation
1. Carefully slide the module into an open slot in an iConverter chassis. Align
the module with the installation guides and ensure that the module is firmly
seated against the backplane. Secure the module by fastening the front panel
thumbscrew (push in and turn clockwise to tighten) to the chassis front. The
CWDM/AD module requires no external power, however, if management is
required, the module must be installed in an iConverter powered chassis with a
Network Management Module (NMM2 Model 8000N-0) or a M2 series or higher
module (such as the iConverter 10/100M2, GM3 or GM4).
2. Connect a single-mode, dual fiber duplex LC cable between the Channel Port
of the CWDM/AD module and the attached device. It is important to ensure
that the wavelength of the CWDM/AD matches the wavelength of the attached
device. Connect both Channel Ports in this manner. Ensure that the transmit
(Tx) is attached to the receive side of the device at the other end, and the
receive (Rx) is attached to the transmit side.
3. Connect a single-mode, single-fiber simplex LC cable between the Common
Ports on the CWDM/AD modules (this connection may be made through fiber
patch panels since the modules may not be co-located) or CWDM/X module.
Make sure the Left/Right designation is followed.
NOTE: For proper installation, a network diagram indicating port designations is
recommended.
NOTE: The iConverter CWDM/AD modules cannot be installed in slots 4, 8, 12 and
16 of a 19-Module Chassis or in the top slot of a 2-Module Chassis or in a 1-Module
Redundant Power Chassis.
Design Considerations
Attenuation (signal loss) of less than 1.9dB will be realized through each port on
the module (see the CWDM/AD Data Sheet for exact attenuation specifications for
model used). Detailed calculations should be performed for each fiber optic link in
the network to ensure the CWDM transceiver has sufficient transmit power.
When calculating optical loss, ensure that the total attenuation, plus a safety factor
(typically 3dB), does not exceed the optical power budget of the transceiver. The
optical power budget is the difference between the transmitter optical output power
and the receiver's optical sensitivity. The transmitter optical output power and
receiver optical sensitivity values can be obtained from the manufacturers of the
respective equipment.
For more information, access Omnitron's CWDM Overview web page to view all
relevant products:
https://www.omnitron-systems.com/products/iconverter-cwdm-multiplexer-cwdm-optical-
add-drop-mux
Page 3
General and Copyright Notice
This publication is protected by U.S. and international copyright laws. All rights reserved. The whole or
any part of this publication may not be reproduced, stored in a retrieval system, translated, transcribed,
or transmitted, in any form, or by any means, manual, electric, electronic, electromagnetic, mechanical,
chemical, optical or otherwise, without prior explicit written permission of Omnitron Systems Technology,
Inc.
The following trademarks are owned by Omnitron Systems Technology, Inc.: FlexPoint
HybridNID
, iConverter
, miConverter
®
®
TM
Omnitron Systems Technology, Inc.
, OST
TM
All other company or product names may be trademarks of their respective owners.
The information contained in this publication is subject to change without notice. Omnitron Systems
Technology, Inc. is not responsible for any inadvertent errors.
Warranty
This product is warranted to the original purchaser against defects in material and workmanship for
a period of ONE YEAR from the date of shipment. You may register your product on the Internet at
https://www.omnitron-systems.com. During the warranty period, Omnitron will, at its option, repair or
replace a product which is proven to be defective.
For warranty service, the product must be sent to an Omnitron designated facility, at Buyer's expense.
Omnitron will pay the shipping charge to return the product to Buyer's designated US address using
Omnitron's standard shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to product malfunctions resulting from improper or inadequate use
and/or maintenance of the equipment by Buyer, Buyer-supplied equipment, Buyer-supplied interfacing,
unauthorized modifications or tampering with equipment (including removal of equipment cover by
personnel not specifically authorized and certified by Omnitron), or misuse, or operating outside the
environmental specification of the product (including but not limited to voltage, ambient temperature,
radiation, unusual dust, etc.), or improper site preparation or maintenance.
No other warranty is expressed or implied. Omnitron specifically disclaims the implied warranties of
merchantability and fitness for any particular purpose.
The remedies provided herein are the Buyer's sole and exclusive remedies. Omnitron shall not be liable
for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort,
or any legal theory.
Environmental Notices
The equipment covered by this manual must be disposed of or recycled in accordance with the Waste
Electrical and Electronic Equipment Directive (WEEE Directive) of the European Community directive
2012/19/EU on waste electrical and electronic equipment (WEEE) which, together with the RoHS
Directive 2015/863/EU, for electrical and electronic equipment sold in the EU after July 2019. Such
disposal must follow national legislation for IT and Telecommunication equipment in accordance with the
WEEE directive: (a) Do not dispose waste equipment with unsorted municipal and household waste. (b)
Collect equipment waste separately. (c) Return equipment using collection method agreed with Omnitron.
The equipment is marked with the WEEE symbol shown to indicate that it must be collected
separately from other types of waste. In case of small items the symbol may be printed only on the
packaging or in the user manual. If you have questions regarding the correct disposal of equipment go
to www.omniton-systems.com/support or e-mail to Omnitron at intlinfo@omnitron-systems.com.
38 Tesla, Irvine, CA 92618, 949.250.6510 tel, 949.250.6514 fax, www.omnitron-systems.com
, NetOutlook
, OmniLight
, OmniConverter
®
®
and the Omnitron logo.
TM
040-08878-001D 2/21
, FlexSwitch
,
TM
TM
, RuggedNet
,
®
®

Advertisement

loading

This manual is also suitable for:

Iconverter 8878-31Iconverter 8878-35Iconverter 8878-39Iconverter 8878-43Iconverter 8878-47Iconverter 8878-51 ... Show all