OPTIONS AND FUNCTIONS
OPTIONS can be selected directly by pressing the
corresponding button (see Control Panel)
If an option is not compatible with the selected
program (see the Programs Table), the corresponding LED
flashes rapidly 3 times and beeps will sound. The option
will not be enabled.
MULTIZONE
If there are not many dishes to be washed, a half
load cycle may be used in order to save water,
electricity and detergent.
Select the wash cycle and then press the
MULTIZONE button: the indicator corresponding to
the chosen rack lights up and the wash cycle starts
only in the upper or lower rack.
Remember to load the upper or lower rack only,
and to reduce the amount of detergent accordingly.
EXTRA DRY
To improve the drying of the dishes, after selecting the
program, press the EXTRA DRY button and the indi-
cator light comes on.
A higher temperature during the final rinse and an
extended drying phase allow for improving drying.
To deselect the option, press the same button again.
The EXTRA DRY option results in the lengthening
of the wash cycle.
TURBO
This option can be used to reduce the duration of
the main programs while maintaining the same wa-
shing and drying performance levels.
After selecting the program, press the Turbo button
and the indicator light will switch on.
To deselect the option, press the same button again.
TABLET (Tab)
This setting allows you to optimize the performance
of the program according to the type of detergent
used.
Press the TABLET button (the indicator light will light
up / the corresponding symbol will light up) if you
use combined detergents in tablet form (rinse aid,
salt and detergent in 1 dose). If you use powder or
liquid detergent, this option should be off.
4
DELAY
The start of the program may be delayed for a period
of time between 0:30 and 24 hours.
1. Select the program and any desired options. Press
the DELAY button (repeatedly) to delay the start
of the program. Adjustable from 0:30 to 24 hours.
With each press of the button, the delay start in-
creases by: 0:30 if selection below 4 hours, 1:00 if
selection is below 12 hours, 4 hours if selection is
above 12 hours. If 24 hours reached, and the but-
ton is pressed, the delayed start is deactivated.
2. Press the START/PAUSE button: the timer will
begin counting down;
3. Once this time has elapsed, the indicator light
switches off and the program begins automatically.
If at the time of the countdown the START/PAUSE
button is pressed again the DELAY option is cancel-
led and the selected program starts automatically.
The DELAY function cannot be set once a pro-
gram has been started.
KEYLOCK
A long press (for 3 seconds) of EXTRA DRY button,
will activate the KEYLOCK function. The KEYLOCK
function will block the control panel except the
ON/OFF button. To deactivate the KEYLOCK, long
press again.
WATER TAP CLOSED – Alarm
Flashes when there is no inlet water or water tap is
closed.
DRAIN OUT
To stop and cancel the active cycle, the Drain Out
function can be used.
A long press of START/PAUSE button, will activate
the DRAIN OUT function. The active program will
be stopped and the water in the dishwasher will be
drained out.