Page 1
EB 8321 EN Translation of original instructions Type 3278 Pneumatic Rotary Actuator Type 3278 Pneumatic Rotary Actuator Actuator area: 160 and 320 cm² Edition January 2021...
Page 2
Note on these mounting and operating instructions These mounting and operating instructions assist you in mounting and operating the device safely. The instructions are binding for handling SAMSON devices. The images shown in these instructions are for illustration purposes only. The actual product may vary.
Contents Safety instructions and measures ..............1-1 Notes on possible severe personal injury ............1-3 Notes on possible personal injury ..............1-4 Notes on possible property damage .............1-5 Warnings on the device ................1-5 Markings on the device ................2-1 Actuator nameplate ..................2-1 Design and principle of operation ...............3-1 Direction of action ..................3-1 Signal pressure routing ................3-1 Fail-safe action ...................3-1...
Page 4
Decommissioning ..................9-1 Removal ....................10-1 10.1 Removing the actuator from the valve ............10-1 10.2 Relieving the spring compression in the actuator ..........10-1 Repairs ....................11-1 11.1 Returning devices to SAMSON ..............11-1 Disposal ....................12-1 Annex......................13-1 13.1 Tightening torques ..................13-1 13.2 Spare parts ....................13-1 13.3 After-sales service ..................13-3...
SAMSON. SAMSON does not assume any liability for damage resulting from the failure to use the de- vice for its intended purpose or for damage caused by external forces or any other external factors.
Page 6
Î Check with the plant operator for details on further protective equipment. Revisions and other modifications Revisions, conversions or other modifications of the product are not authorized by SAMSON. They are performed at the user's own risk and may lead to safety hazards, for example. Fur- thermore, the product may no longer meet the requirements for its intended use.
Safety instructions and measures Referenced standards, directives and regulations According to the ignition risk assessment performed in accordance with EN 13463-1:2009, section 5.2, the non-electrical actuators do not have their own potential ignition source even in the rare incident of an operating fault. As a result, they do not fall within the scope of Di- rective 2014/34/EU.
Safety instructions and measures 1.2 Notes on possible personal injury WARNING Risk of personal injury due to preloaded springs. Actuators with preloaded springs are under tension. Î Only open the actuator housing to safely relieve the energy of the spring compres- sion following the instructions in this document.
Risk of actuator damage due to the use of unsuitable tools. Certain tools are required to work on the actuator. Î Only use tools approved by SAMSON. Risk of actuator damage due to the use of unsuitable lubricants. The lubricants to be used depend on the actuator material. Unsuitable lubricants may corrode and damage surfaces.
Max. Luftdruck Type Max. Air pressure Federbereich Spring Range Sicherheitsstellung wird vom Anbau des Antriebs an das Ventil bestimmt! Fail-safe position is determined by the attachment of the actuator to the valve! Fig. 2-1: Nameplate of Type 3278 Actuator EB 8321 EN...
Design and principle of operation 3 Design and principle of operation 3.2 Signal pressure routing The single-acting Type 3278 Rotary Actuator with spring return mechanism is mounted on When the signal pressure fails, the mounted butterfly valves and other final control ele- valve is moved to its fail-safe position.
Page 14
Actuator shaft Diaphragm plate Diaphragm Housing 8, 9, 10 Springs Vent plug 8 Spring number 1 Handwheel 9 Spring number 2 Screw 10 Spring number 3 Stop bolts Signal pressure connection Screw Fig. 3-1: Functional diagram of Type 3278 EB 8321 EN...
Positioner mounting kit A mounting kit with a bracket, intermediate piece and screws is required to attach a non-SAMSON positioner (according to VDI/ VDE 3845). The positioner is mounted on the side opposite to the flange connection. Actuator area Material number of mounting kit 160 cm²...
Page 16
Design and principle of operation Table 3-1: Technical data for Type 3278 Permissible signal pressure 6 bar Actuator area 160 cm² · 320 cm² Opening angle 90° No. of springs Signal pressure ranges 7 (through different spring combinations) Permissible temperatures –35 to +90 °C in continuous operation...
Page 17
Design and principle of operation Dimen- ØD G¼ sional drawings Flange 1 Flange 2 Stop bolts to limit opening angle EB 8321 EN...
Risk of lifting equipment tipping over and damage. Report any damage to risk of damage to lifting accessories due to SAMSON and the forwarding agent exceeding the rated lifting capacity. (refer to delivery note). Î Only use approved lifting equipment and 3.
Shipment and on-site transport Transport instructions WARNING − Protect the actuator against external in- Risk of injury due to incorrect lifting without fluences (e.g. impact). the use of lifting equipment. − Do not damage the corrosion protection Lifting the actuator without the use of lifting (paint, surface coatings).
Special storage instructions for elastomers Î Avoid long storage times. Elastomer, e.g. actuator diaphragm Î Contact SAMSON in case of different − To keep elastomers in shape and to pre- storage conditions or longer storage vent cracking, do not bend them or hang times.
Risk of actuator damage due to the use of 5.2 Mounting the device unsuitable tools. Î Only use tools approved by SAMSON. Depending on the version, SAMSON control valves are either delivered with the actuator already mounted on the valve or the valve and actuator are delivered separately.
(11) which corre- without the need for additional hook-up. sponds to the upper bench range value. In combination with SAMSON Type 3766 Turn the other stop bolt (42.1) until the and Type 3767 Positioners, a ready-made butterfly valve stops at an opening angle pipe connection with a connecting plate is of 70°.
Page 25
Installation b) Fail-open valve 1. Loosen stop bolts (42.1 and 42.2). 2. Apply a signal pressure to the signal pressure connection (11) which corre- sponds to the upper bench range value (see nameplate). 3. Adjust the stop bolt for closed position (42.1) at the point where the butterfly valve is completely closed.
Î Add any new values to the nameplate. If necessary, contact SAMSON to obtain a new nameplate. 6.1 Throttling service − The Type 3278 Pneumatic Rotary Actua- tor with 160 or 320 cm² actuator area is designed for a maximum supply pressure of 6 bar when used for throttling service.
Malfunctions 7 Malfunctions Read hazard statements, warnings and caution notes in the 'Safety instructions and mea- sures' section. 7.1 Troubleshooting Malfunction Possible reasons Recommended action Actuator shaft does not Actuator is blocked. Check attachment. move on demand. Remove the blockage. Insufficient signal Check the signal pressure.
Risk of actuator damage due to the use of unsuitable tools. WARNING WARNING Î Only use tools approved by SAMSON. Risk of personal injury due to exhaust air being vented. The actuator is operated with air. As a result, air is vented during operation.
SAMSON's After-sales tion 8.5.2) Service. − Only use original spare parts by 8.3 Mounting the actuator on SAMSON, which comply with the original the valve after service or specifications. conversion work 8.1 Periodic testing Î Mount the actuator (see the 'Installation' section).
Servicing and conversion 4. Place on diaphragm case (1) and refas- It is possible to subsequently change the ten it to the housing (5) with bolts (40), bench range by removing or adding spring washers (54) and nuts (50). 8, 9 or 10 in the housing (see Table 8-4). 1.
Servicing and conversion 8.6 Ordering spare parts and operating supplies Contact your nearest SAMSON subsidiary or SAMSON's After-sales Service for infor- mation on spare parts, lubricants and tools. Spare parts See Annex for details on spare parts. Lubricant See document u AB 0100 for details on suitable lubricants.
Decommissioning 9 Decommissioning To decommission the actuator for service work or before removing it from the valve, The work described in this section is only to proceed as follows: be performed by personnel appropriately 1. Put the control valve out of operation. qualified to carry out such tasks.
Removal 10 Removal − The actuator is put out of operation (see the 'Decommissioning' section). The work described in this section is only to be performed by personnel appropriately 10.1 Removing the actuator qualified to carry out such tasks. from the valve DANGER Î...
Î Do not perform any repair work on your side of your shipment so that the docu- own. ments are clearly visible. Î Contact SAMSON's After-sales Service 4. Send the shipment to the address given for repair work. on the RMA.
Disposal 12 Disposal Î Observe local, national and internation- al refuse regulations. Î Do not dispose of components, lubricants and hazardous substances together with your household waste. EB 8321 EN 12-1...
You can reach our after-sales service at aftersalesservice@samsongroup.com. Addresses of SAMSON AG and its subsid- iaries The addresses of SAMSON AG, its subsid- iaries, representatives and service facilities worldwide can be found on our website (www.samsongroup.com) or in all SAMSON product catalogs.
Need help?
Do you have a question about the 3278 and is the answer not in the manual?
Questions and answers