How To Install The Unit; Space For Outside Air Flow; Unit Installation - LG W051CS SSF Owner's Manual

Hide thumbs Also See for W051CS SSF:
Table of Contents

Advertisement

Available languages

Available languages

How to Install the Unit

1
Measure the space for installation to assure
a good fit. The air conditioner must be
installed firmly into place to prevent vibration
and noise.
2
Avoid exposure to direct sunlight.
3
Remove all obstacles from the rear of the unit.
There must be at least 50 cm (20 in.) of
cleared space around the rear of the unit.
Obstacles restricting the airflow may reduce
the cooling efficiency of the unit.
4
The unit should be installed with a slight tilt
towards the outside to allow condensed water
to drain. (About 10~15 mm or 1/4 bubble with
Level)
Foam
Awning
Cooled air
CAUTION
● The external grille must be exposed outside
for air discharge.

Space for Outside Air Flow

Fence
Heat
radiation
10~15 mm
Over 50 cm

Unit Installation

1/4 Bubble
Level
AIR IN
AIR OUT
100 mm minimum
OPTION A
45° BRICK CUT AWAY
TO CLEAR LOUVRES
FRONT
BRICK
WALL
100 mm
TOP
VIEW
AIR IN
LOUVRE
AIR OUT
OPTION B
CAUTION
● The power cord must be connected to an
independent circuit. The green wire must
be grounded.
Stuff the foam between the top of the unit
and the wall to prevent air and insects from
getting into the room.
EN
INSTALLATION
9
AIR IN
45° BRICK CUT AWAY
TO CLEAR LOUVRES
BRICK
WALL
AIR IN
100 mm
The Foam