  • Page 1 Operating Instructions Level Switch MPC2000 MPC2 BA1014N/08/en/05.10 71114533...
  • Page 2 Basic device layout of the Magnet Level Switch MPC2 Analog input (status) ® Local HART (Ex d) Browser Average Temperature Prothermo NMT539 Level Switch MPC2 Host system communicayion Tankvision NR30(MDP1/F) Degital output Analog input (status) ® HART (Ex d) Promonitor NRF560 Oil leak detector NRR261 NAR300 Endress+Hauser...
  • Page 3: Table Of Contents

    3.1 Incoming acceptance, transport, storage ..10 Contact addresses of Endress+Hauser ... 21 Assembly and Installation ..11 10.
  • Page 4: Safety Instructions

    This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution! Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Endress+Hauser...
  • Page 5: Notes On Safety Conventions And Symbols

    A terminal which must be connected to earth ground prior to making any other connection to the equipment Equipotential connection (earth bonding) A connection made to the plant grounding system which may be of type e.g. neutral star or equipotential line according to national or company practice Endress+Hauser...
  • Page 6: Identification

    With fin (single fin, 1 x FRT orverflow detection With cable connector Outer pipe type (side-side) double fin) 1 xCRT orverflow detection (TF16-11/TF22-13/ Outer pipe type (side-bottom) 2 x Level TF22-15/TF28-18) 3 x Level 4 x Level Fig. 1: Name plate Endress+Hauser...
  • Page 7: Ordering Information

    N 80A 300lbs RF, SUS304, JPI flange 7S-15 80A 300lbs RF, SUS316, JPI flange 7S-15 W 100A 150lbs RF, SUS304, JPI flange 7S-15 X 100A 150lbs RF, SUS316, JPI flange 7S-15 Special version, TSP-no. to be spec. MPC2- Product designation (part 1) Endress+Hauser...
  • Page 8 • minimum setting length – 1 point length (H) is more than 300mm. Please specify alarm interval with more than 150mm. Scope of delivery Caution! It is essential to follow the instructions concerning the unpacking, transport and storage of measuring Endress+Hauser...
  • Page 9: Scope Of Delivery

    Level Switch MPC2 2 Identification instruments given in the chapter "Incoming acceotance, transport, storage" . The scope of delivery consists of: • Assembled instrument Accompanying documentation: • Operating Instruction (this manual) Endress+Hauser...
  • Page 10: Installation

    Follow the safety instructions and transport conditions for instruments of more than 18 kg. 3.1.3 Storage Pack the measuring instrument so that is protected against impacts for storage and transport. The original packing material provides the optimum protection for this. The permissible storage temperature is -10... + 60 °C Endress+Hauser...
  • Page 11: Assembly And Installation

    Terminal box Terminal Iron core Iron core Top mounted flange Top mounted flange Nozzle flange 25A/1” 25A/1” Spring Cable connector Spring Displacer Displacer wire wire Ø48.6 Nozzle Ø48.6 Displacer flange Displacer External pipe External pipe 25A/1” 25A/1” Drain cap Endress+Hauser...
  • Page 12 Iron core Iron core Terminal box Terminal box Top mounted flange Top mounted flange Nozzle flange 25A/1” Spring Spring Cable connector 150 mm Displacer wire Displacer wire Ø48.6 Nozzle Ø48.6 Displacer Flange Displacer External pipe External pipe 25A/1” Drain cap Endress+Hauser...
  • Page 13 Terminal box Iron core Iron core Top mounted flange Top mounted flange Nozzle Flange 25A/1” 25A/1” Spring Spring Cable connector 150 mm Displacer wire Displacer wire Nozzle flange Displacer Displacer External pipe External pipe Ø48.6 Ø48.6 25A/1” Drain cap 25A/1” Endress+Hauser...
  • Page 14 Terminal box Iron core Iron core Top mounted flange Top mounted flange Nozzle flange 25A/1” 25A/1” Spring Spring Cable connector 150 mm Displacer wire Displacer wire Displacer Nozzle flange 25A/1” Displacer External pipe External pipe Ø48.6 Ø48.6 25A/1” Drain cap Endress+Hauser...
  • Page 15: Overflow Alarm

    Weight type: (order code: 030 "Switch Count"...5; 1xFRT overflow detection) Ø136 Cover Guide pipe Magnet Micro switch Iron core Terminal box Test wire seal parts Top mounted flange 100A/4” nozzle Spring Weight wire Test wire Ø70 Weight Tank roof Tank roof pushes the weight up Endress+Hauser...
  • Page 16 Internal pipe type With fin (single fin, 1 x FRT orverflow detection With cable connector Outer pipe type (side-side) double fin) 1 xCRT orverflow detection (TF16-11/TF22-13/ Outer pipe type (side-bottom) 2 x Level TF22-15/TF28-18) 3 x Level 4 x Level Endress+Hauser...
  • Page 17: Mounting (Ex Type)

    • Be careful not to bend intermediate shaft, when mounting spring and body. • Mount locking screw of spring tight. • After mounting as follows, connect with pipe. Intermediate part Body Terminal box Cable entry Spring Displacer lock nut Triangular joint Ø49 Displacer Endress+Hauser...
  • Page 18: Wiring

    Level Switch MPC2 5 Wiring Wiring The figure shows the each switch contact condition when level is normal. Teminal Micro switch 1 contact 2 contacts 3 contacts 4 contacts Endress+Hauser...
  • Page 19: Alarm Contact Changing

    Operating and Maintenance There are no special notes about operating and Maintenance, but if the liquid is adhesive, please clean sealpipe, displacer, internal pipe. Precaution for high temperature Please refer to MPC2 series Technical Informantion "Instruction for use in high temperature". Endress+Hauser...
  • Page 20: Troubleshooting

    Level Switch MPC2 9 Troubleshooting Troubleshooting Spare Parts You can order spare parts directly from your Endress+Hauser service organization by the corresponding spare parts. 1 point 2 points 3 - 4 points Spear parts No. Spear parts No. O-ring, main body, NBR Flange packing, D120 X D70 X 2T...
  • Page 21: Failure And Remedy

    In case of disposal, please separate the different components according to their material consistency. Contact addresses of Endress+Hauser The addresses of Endress+Hauser are given on the back cover of this operating manual. If you have any questions, please do not hesitate to contact your E+H representative.
  • Page 22: Technical Data

    TIIS : max. AC250V, 1050VA max. DC250V, 120VA Allowable contact capacity : max. AC250V, 4.2mA (1~2 points) max. AC250V, 2.8mA (3~4 points) Please contact Endress+Hauser about specifications Hysteresis Standard: 1,2 : better than 7~25mm (in case of density = 1g/cm...
  • Page 23 Weather proof type (W) : 20 a.b.c (cable connector) Color Metallic silver (internal type is not painted) Dimendion Internal pipe type: Internal pipe length max. 4000mm External pipe type: mounting nozzle interval (specified) Caution! Side and bottom flange are 25A/1" equivalent. Endress+Hauser...
  • Page 24 "CAJ?P?RGML MD AMLR?KGL?RGML $EAR CUSTOMER "ECAUSE OF LEGAL DETERMINATIONS AND FOR THE SAFETY OF OUR EMPLOYEES AND OPERATING EQUIPMENT WE NEED THIS $ECLARATION OF CONTAMINATION WITH YOUR SIGNATURE BEFORE YOUR ORDER CAN BE HANDLED 0LEASE INCLUDE THE COMPLETELY FILLED IN DECLARATION WITH THE DEVICE AND THE SHIPPING DOCUMENTS IN ANY CASE !DD ALSO SAFETY SHEETS AND  OR SPECIFIC HANDLING INSTRUCTIONS IF NECESSARY 4YPE OF DEVICE  SENSOR 3ERIAL NO...
  • Page 25 WWW.endress.com/worldwide Japan Endress + Hauser Yamanashi Co., Ltd. 862-1 Mitsukunugi Sakaigawa-cho Fuefuki-shi Yamanashi, 406-0846 Japan Phone: ++81 55 266 4964 Fax: ++81 55 266 4969 BA1014N/08/en/05.10 71114533 FM+SGML 6.0...