Wind Direction Sensor - Global Water WE100 Manual

Table of Contents

Advertisement

VII. Wind Direction Sensor
a. Wind Direction sensor specifications.
Output:
Range:
Accuracy:
Operating Voltage:
Current Draw:
Warm Up Time:
Operating Temp:
Size:
Weight:
b. The sensor is a two-wire sensor using the red wire for power and the
black wire for the output signal. Warning: Always connect the
sensor with the power turned off.
c. The ridge on the fixed portion of the sensor represents the 0° direction
of the sensor. The sensor comes with a stainless steel elbow that can
be mounted on a 1" diameter tube. For best results ensure that the
sensor is mounted parallel to the ground surface.
d. A wind direction sensor produces a ratiometric voltage signal. That
voltage signal is transformed into a 4-20 mA sensor output signal.
Global Water
800-876-1172 • globalw.com
4-20 mA
0 to 360° (352° electrical, 8° open)
1% of full scale
10-36VDC
Same as sensor output
3 seconds minimum
-40° to +55°C
8 ½" diameter x 10 ½" long
1 lb.