  • Page 1 Venice Compact digital electric D.W.H. heater INSTRUCTION & INSTALLATION GUIDE...
  • Page 3: Table Of Contents

    3. Description and information..............................4 4. Installation....................................5 5. Operation....................................10 6. Protection against magnesium anode oxidation.........................11 7. Periodic maintenance ................................11 8. Rointe Product Guarantee...............................12 9. European Directive..................................13 10. Dimensions & Technical Characteristics..........................14 11. Certificate of Guarantee................................15 PLEASE NOTE Thank you for choosing the VENICE D.H.W. compact heater. Manufactured with the highest quality components, the VENICE Compact was designed for you.
  • Page 4: General

    • If the power cable (if included) suffers damage, it must be replaced by Rointe’s official Technical Service (please call 0203 321 5929) or by a competent professional with the appropriate training, in order to avoid any risk.
  • Page 5: Installation

    If the device is activated, you must call the Rointe Technical Service. The control lights (depending on the model) indicate the current mode of the unity.
  • Page 6 Pressure reducing valve (included) * These images are only for reference. Check the Building Regulations (PART G) for specific details and accessories required to perform a proper installation. The Rointe water heaters must be installed by an installer with a valid Unvented Water Heaters Installer certification.
  • Page 7 If the pressure in the water network exceeds the amounts indicated in section 1, it is necessary to install a pressure reduction valve, otherwise the water heater will not work properly. Rointe does not assume any responsibility for problems arising from incorrect use of the water heater.
  • Page 8 4.5. Expansion relief valve This must be installed between the pressure reducing valve and the water heating . No other valve should be fitted between this valve and the cylinder. The expansion relief valve contains a non return valve. 4.6. Expansion vessel The expansion vessel MUST be fitted to the safety group.
  • Page 9 – Where a single pipe serves a number of discharges such as in blocks of flats, the number served should be limited to not more than six systems so that any installation discharging can be traced reasonably easily. The single common discharge pipe should be at least one pipe size larger than the largest individual discharge pipe to be connected.
  • Page 10: Operation

    Calculated Example 1 The example below is for a 1/2” diameter temperature relief valve with a discharge pipe (D2) having 4 22mm elbows and a length of 7m from the tundish to the point of discharge. The maximum resistance allowed for a straight length of 22mm copper discharge pipe (D2) from a 1/2” diameter temperature relief valve is 9.0m.
  • Page 11: Protection Against Magnesium Anode Oxidation

    To replace the magnesium anode, please contact the Rointe Technical Service on 0203 321 5929. 7. PERIODIC MAINTENANCE Under normal operating conditions, and with a high temperature on the surface of the electrical resistance, lime scale deposits can often occur.
  • Page 12: Rointe Product Guarantee

    ROINTE. Any incident that you might detect in your ROINTE product can be sorted by the product seller or quickly by the manufacturer. Please contact ROINTE by telephoning 0203 321 5929 for Technical Support. Alternatively, you can email ROINTE at support@rointe.co.uk, through which we will instruct you on how to solve the...
  • Page 13: European Directive

    8.2.5. The product has not been subjected to excessive pressure or electrolytic actions from dissimilar materials or attack from salt deposits. 8.3. The Technical Service department of ROINTE will advise you if you need to purchase any parts not covered under the guarantee or out of guarantee.
  • Page 14: Dimensions & Technical Characteristics

    10. DIMENSIONS & TECHNICAL CHARACTERISTICS TECHNICAL INFORMATION Submerged copper heating element Enamelled steel tank Magnesium anode protector CFC-free polyurethane insulation foam External casing in ABS 257 mm 324 mm 372 mm Maximum working pressure (bars) Protection Grade IPX4 Energy Classification FUNCTIONS External thermal regulator dial INSTALLATION...
  • Page 17 NOTES...
  • Page 18 NOTES...
  • Page 20 Venice Compact digital electric D.W.H. heater Rointe Spain & Portugal P.I. Vicente Antolinos C/ E, parc. 43 30140 Santomera (Murcia) T. (ES) 902 158 049 T. (PT) 221 200 114 www.rointe.com www.rointe.pt sat@rointe.com Rointe UK & Ireland Catalyst House, 720 Centennial Court, Centennial Park, Elstree, Herts, WD6 3SY T.