Revolutionary full color event battery table lamp (24 pages)
Summary of Contents for ProLights Astra Beam260IP
Page 1
Astra Beam260IP IP65 moving beam light with 260 W PRO long life lamp (6.000 hours) USER MANUAL English version REV.01-03/21...
Page 2
PROLIGHTS product are trademarks OWNED or licensed by Music & Lights S.r.l., its affiliates, and subsidiaries. PROLIGHTS is a registered trademark by Music & Lights S.r.l. All right reserved. Music & Lights – Via A. Olivetti, snc - 04026 - Minturno (LT) ITALY.
• Do not reapply power until repairs have been completed. • Refer any service operation not described in this manual to PROLIGHTS Service team or an authorized PROLIGHTS service center. Installation •...
Page 5
• This device emits potentially dangerous optical radiation and is identified in the cat- egory of Risk Group 1 according to EN 62471. Radio receiver* • This product contains a radio receiver and/or transmitter: • Maximum output power: 17 dBm. • Frequency band: 2.4 GHz. PROLIGHTS - Astra Beam260IP...
Page 6
• Warning! Disconnect the fixture from AC mains power and allow to cool for at least 10 minutes before handling. • Only technicians who are authorized by PROLIGHTS or Authorised service partners are permitted to open the fixture. • Users may carry out external cleaning, following the warnings and instructions pro- vided, but any service operation not described in this manual must be referred to a qualified service technician.
• FCLASTRAB260IP: flight case for 2 pcs of ASTRABEAM260IP; • OSIP: IP65 quick-lock omega bracket compatible with IP65 moving heads; • IPTESTBOX: portable vacuum and pressure tester for ProLights IP fixtures; • UPBOX2: Firmware uploader kit, USB IN, 3-pin XLR DMX OUT.
Warning! When clamping the fixture to a truss or other structure at any angle, use clamps of half-cou- pler type. Do not use any type of clamp that does not completely encircle the structure when fastened. C6002 RSR Steel security cable clamp OSIP 108 mm 4.2 in Fig. 03 PROLIGHTS - Astra Beam260IP...
• Connect the power connector into the Mains input socket (100-240 VAC-50/60 Hz). • The product is then ready for its operations and can be controlled through the available input sig- nals on board. • To disconnect power from the product, disconnect the Mains from the socket. PROLIGHTS - Astra Beam260IP...
... . DMX IN DMX OUT DMX IN DMX OUT DMX IN DMX OUT DMX IN DMX OUT DMX512 Controller Fig. 06 - Example 17 DMX channels configuration PROLIGHTS - Astra Beam260IP...
(Protocol, Net, Subnet, Universe, Start Channel and IP Address, Ethernet to DMX No/Yes). • About the IP addresses is recommended to set 002.xxx.xxx.xxx or 010.xxx.xxx.xxx. • The submask net is fixed at 255.0.0.0. PROLIGHTS - Astra Beam260IP...
If the ASTRABEAM260IP protocol selected is ArtNet / sACN, the WDMX module will retransmit the DMX values contained in the ArtNet / sACN signal received from the ASTRABEAM260IP. NOTE: Artnet and sACN have higher priority on DMX if they are connected to transmitter. PROLIGHTS - Astra Beam260IP...
• The wireless icon on the receiver display indicates the received signal strength. WDMX TO DMX (RX) This function enable or disable the retransmission of the wireless DMX signal received throught the DMX port on the receiver side. PROLIGHTS - Astra Beam260IP...
• Used to access the menu tree or to return a previous menu window. • To switch on the display throught the battery. • LED indicator for Wireless dmx (color red and green). • LED indicator for Ethernet network.(color orange) PROLIGHTS - Astra Beam260IP...
Allows you lock the buttons on the control panel by a pass- word. Press following combi- nations (password) in order to access to the user menu : UP, DOWN, UP, DOWN. MOVEMENT PAN REVERSE Allows you to enable/disable Pan movement. PROLIGHTS - Astra Beam260IP...
Page 18
To transfer the same menu CONFIGURATION ADDRESS settings of one fixtures to all the other in the daisy chain, WITH DMX including or not the dmx ADDRESS address. ADVANCED RESET To reset these functions. TILT PAN & TILT PROLIGHTS - Astra Beam260IP...
Page 19
TEMP,… FANS SPEED NEAR SOURCE To see the speed of the fans. FAN, BASE FAN,… WIRELESS POWER ON CYCLE To check the wireless quality. QUALITY CHANNEL PAN... To see the dmx value of those VALUE channels. PROLIGHTS - Astra Beam260IP...
Fixture will be powered on without reset on pan/tilt then power on pan/tilt movements movements. DOWN home screen after Calibration process Disable Lamp Fan Error for Lamp calibration. power on ENTER + UP Bootloader Force firmware upgrade. then power on PROLIGHTS - Astra Beam260IP...
128 ÷ 188 Open 189 ÷ 190 Randon from slow to fast 191 ÷ 251 Open 252 ÷ 255 COLOR WHEEL Indexed Open 000 ÷ 003 Open + DARK RED 004 ÷ 007 DARK RED 008 ÷ 011 PROLIGHTS - Astra Beam260IP...
Page 24
Gobo 11 from slow to fast 228 ÷ 234 Gobo 12 from slow to fast 235 ÷ 241 Gobo 13 from slow to fast 242 ÷ 248 Gobo 14 from slow to fast 249 ÷ 255 PROLIGHTS - Astra Beam260IP...
Page 25
From fast to slow 193 ÷ 255 FROST Continuous Lineary from 0% to 100% 000 ÷ 255 FOCUS Lineary from in to out 000 ÷ 255 FOCUS FINE Lineary from in to out 000 ÷ 255 PROLIGHTS - Astra Beam260IP...
Page 26
RESET GOBO 076 ÷ 077 RESET SHUTTER 078 ÷ 079 RESET OTHER 080 ÷ 081 LAMP OFF 082 ÷ 083 LAMP ON 084 ÷ 085 Reserved 086 ÷ 253 FACTORY DEFAULT OF CONTROL FUNCTIONS 254 ÷ 255 PROLIGHTS - Astra Beam260IP...
15 - COLOR WHEEL DARK BLUE DARK RED CTB=10000K ORANGE CTO2=3200K AQUAMARINE CTO1=2600K DEEP GREEN CYAN MAGENTA LAVANDER YELLOW PINK Fig. 10 PROLIGHTS - Astra Beam260IP...
PAN and TILT locks for added stability while replacing the lamp (1). See the "PAN AND TILT LOCK" paragrap. Then remove the six market screws to remove rear cover (2). Unclip the rear cover safety cable. PROLIGHTS - Astra Beam260IP...
Page 30
Remove the eight marked screws. Safety cable Cable connected Module to the module Unclip the heatsink module safety cable. Slow remove the cable connected to the module and re- move the heatsink module. PROLIGHTS - Astra Beam260IP...
Page 31
Carefully inspect gaskets for signs of wear such as cracking or harden- ing, deformities, or alignment issues before replacing the lamp. Then insert the new lamp using the reverse procedure. Fig. 11 PROLIGHTS - Astra Beam260IP...
(3) to center the hotspot of the lamp on the center of the projection (4). NOTE: after to have close the housing please check the correct sealing with the IPTESTBOX (see "19 - TEST OF THE RATED IP65" paragraph). Fig. 12 PROLIGHTS - Astra Beam260IP...
• or the stepping motor is defective; • or its driving IC on the PCB is defective; • or the product is not located in the default position after the reset of the fixture. [TILT LOCKED] Tilt is locked. PROLIGHTS - Astra Beam260IP...
Page 34
Cyan the lamp has been switched OFF. [LAMP AIR OUT FAN Air out blower for cooling the lamp Cyan ERR.] failed, the lamp has been switched OFF. [FAN PCB ERROR] Fan 5U PCB not detected. Cyan PROLIGHTS - Astra Beam260IP...
Before removing rear cover, place the head in a horizontal position and engage both the PAN and TILT locks for added stability. See the "PAN AND TILT LOCK" paragrap. Loosen and remove the marked screws and opening the head covers (1) from both sides. Unclip the heatsink module safety cable. PROLIGHTS - Astra Beam260IP...
Page 37
Use a soft cloth dampened with any detergent liquid for cleaning glass to remove the dirt from the reflectors, from the lenses and filters. PROLIGHTS - Astra Beam260IP...
Page 38
Loosen and remove the market screws from both sides (total four screws). Remove the modules. NOTE: after to have close the housing please check the correct sealing with the IPTESTBOX (see "19 - TEST OF THE RATED IP65" paragraph). Fig. 14 PROLIGHTS - Astra Beam260IP...
19 - TEST OF THE RATED IP65 After servicing to controll the correct sealing to use the IPTESTBOX. Remove the gore valve from the connections panel. Connect the air hose to the IPTESTBOX by inserting the quick-connect fitting into the coupler. PROLIGHTS - Astra Beam260IP...
Page 40
Remove the gore valve on the rear connection heatsilk module (4) and insert the hex socket cap head included in the IPTESTBOX box (5). For the operating procedure for using the instrument, refer to the IPTESTBOX user manual. Fig. 15 PROLIGHTS - Astra Beam260IP...
WARNING: the use of alcohol or any other detergent could damage the lenses. • All other service operations on the product must be carried out by PROLIGHTS, its approved service agents or trained and qualified personnel.
• Check if the Fuse is intact and eventually replace it if fault. necessary. • Contact the PROLIGHTS Service or authorized service partner. Do not remove parts and/or covers, or carry out any repairs or service that are not described in...
Need help?
Do you have a question about the Astra Beam260IP and is the answer not in the manual?
Questions and answers