Download Print this page
Yale UNI-TJ50BC Series Installation Instructions
Yale UNI-TJ50BC Series Installation Instructions

Yale UNI-TJ50BC Series Installation Instructions

Non handed door closers

Advertisement

Quick Links

UNI Stop/Holder
UNI-TJ50BC Series
Sized Closers
UNI-TJ51(BF) Series
Multi-Sized Closers
Right Hand Door - RH
Left Hand Reverse - LHR
Right Hand Door - RH
Left Hand Reverse - LHR
!
NOTE: For special applications a separate door and frame preparation template is packed with these instruction. Use this
instruction sheet for installation sequence and closer adjustments only.
!
It is recommended that the door, on which the door closer will be installed, be hung on ball bearing hinges. Door must swing
freely.
!
Door and Frame must be properly reinforced, or use of special fasteners employed, to prevent the mounting screws from pulling
out.
!
All dimensions are given in inches with corresponding metric dimensions (millimeters) in parenthesis.
Components
Power Adjustment Screw (3/16 Hex Drive)
Closer
Size
Stamp
Pinion Cap
Installation Instructions
Non Handed Door Closers
Door Stop...Door Holder...Door Closer
(On-Off Hold-Open Control) Not UL Listed
"BC" Valve
"L" Valve
"S" Valve
These installation instructions cover either of the models illustrated.
80-9350-2517-010 (06-09)
AN INCORRECTLY INSTALLED OR IMPROPERLY
ADJUSTED DOOR CLOSER CAN CAUSE
PROPERTY DAMAGE OR PERSONAL INJURY.
THESE INSTALLATION INSTRUCTIONS SHOULD
BE FOLLOWED TO AVOID THE POSSIBILITY OF
MISAPPLICATION OR MISADJUSTMENT.
Series UNI-TJ50
Door Stop...Door Closer
UL Listed for Fire Doors
Series UNI-TJ150
Non Hold Open &
Hold Open (TJ150) Models
Sized
(Sizes 2,3,4,5,6)
UNI-TJ52BC UNI-TJ152BC
UNI-TJ53BC UNI-TJ153BC
UNI-TJ54BC UNI-TJ154BC
UNI-TJ55BC UNI-TJ155BC
UNI-TJ56BC UNI-TJ156BC
Right Hand Reverse - RHR
Right Hand Reverse - RHR
2 sex-nuts
Rod Unit
(Arm Number
Stamp)
Main-Arm
Screw
Rod Screws
Slide Unit
Holder Control
Multi-Sized
(Sizes 3 thru 6)
UNI-TJ51
UNI-TJ151
(Sizes 1 thru 4)
UNI-TJ51BF
UNI-TJ151BF
Left Hand Door - LH
Left Hand Door - LH
Optional Cover
Optional Thru-Bolt
&
Grommet Nuts

Advertisement

loading

Summary of Contents for Yale UNI-TJ50BC Series

  • Page 1 Hold Open (TJ150) Models Non Handed Door Closers UNI Stop/Holder Multi-Sized Sized (Sizes 3 thru 6) (Sizes 2,3,4,5,6) UNI-TJ50BC Series AN INCORRECTLY INSTALLED OR IMPROPERLY UNI-TJ51 UNI-TJ52BC UNI-TJ152BC ADJUSTED DOOR CLOSER CAN CAUSE Sized Closers PROPERTY DAMAGE OR PERSONAL INJURY.
  • Page 2 Hollow-Metal or Wood Openings Template Opening Dimension “A” Stop Hold-Open inches 85° 90° 9-1/8 90° 95° 8-3/8 95° 100° 7-3/4 100° 7-3/8 105° 105° 110° 6-3/4 6-1/2 110° 115° Side Elevation Reveal Hinge Number Pinion Cap inches/(mm) Stamp Installation Sequence “BC”...
  • Page 3 Aluminum Openings Template Opening Dimension “A” Stop Hold-Open inches 85° 90° 9-1/8 90° 95° 8-3/8 95° 100° 7-3/4 100° 7-3/8 105° 105° 110° 6-3/4 6-1/2 110° 115° Side Elevation Hinge or Pivot Reveal Number Pinion Cap inches/(mm) Stamp Installation Sequence “BC”...
  • Page 4 Tel: (800)-438-1951 • Fax: (800)-338-0965 Copyright © 1999, 2009, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. www.yalecommercial.com Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. Page 4...

This manual is also suitable for:

Uni-tj51 seriesUni-tj51bf seriesUni-tj52bcUni-tj152bcUni-tj53bcUni-tj153bc ... Show all