Product Description; Technical Data - Riello 7200/2-1500 HV PLUS Installation Instructions Manual

Solar storage cylinders
Table of Contents

Advertisement

Riello 7200/2 HV PLUS

3 Product description

The solar storage cylinders can be integrated into solar
systems for the production of domestic hot water.
The main technical elements of the design of the solar
storage cylinder are:
- the careful study of the geometries of the tank and the
coils that allow you to obtain the best performance in
terms of stratification, heat exchange and reactivation
times
- the regulation of the connections to various heights for
employing various types of heat generators, without
influencing the stratification
- the polyurethane insulation without any CFC and the

4 Technical data

DESCRIPTION
Type of storage cylinder
Storage cylinder layout
Heat exchanger layout
Storage cylinder capacity
Useful non-solar volume (Vbu)
Diameter with insulation
Diameter of storage cylinder without insulation
Height without insulation
Height with insulation
Insulation thickness
Total net weight
First magnesium anode (Ø x length)
Second magnesium anode (Ø x length)
Flange diameter (external/internal)
Diameter/length of sensor socket
Sleeve for electric heating element (**)
Coil water capacity
Coil heat exchange surface area
Power absorbed by coil (*)
Domestic hot water production (*)
Flow required at coil (*)
Top coil water capacity
Top coil heat exchange surface area
Power absorbed by top coil (*)
Hot water production – top coil (*)
Flow required at top coil (*)
Maximum operating pressure
Maximum operating temperature
Discharges according to EN 12897:2006
(∆T=45 °C, ambient 20°C and storage at 65°C)
Insulation type
Maximum operating pressure of coil
Maximum working temperature of coil
NL performance factor
(*) In accordance with DIN 4708 with a ΔT of 20°C (80°/60°C) at the coil.
(**) Electrical heating element (not supplied)
elegant outer covering to limit dispersion and to im-
prove efficiency
- the use of the flange to facilitate cleaning and mainte-
nance
- the use of the magnesium anode with an "anti-corro-
sion" function
The storage cylinders can be equipped with a specific so-
lar regulator and they can easily be inserted into solar
system where the boilers or thermal systems act as auxil-
iary producers of heat.
7200/2
1500 HV PLUS
Vitrified
Vertical
Vertical
1390
525
1200
1000
2120
2185
100
325
32x700
32x400
290/220
8/200
1" 1/2
19,4
3,4
88
2200
3,8
10,4
1,8
47
1200
2
8
99
162
3,89
Soft PU
10
110
55
4
7200/2
2000 HV PLUS
1950
l
800
l
1300
mm
1100
mm
2370
mm
2470
mm
100
mm
540
kg
mm
mm
mm
mm
mm
28,1
L
m 2
4,6
120
kW
2900
l/h
5,2
m3/h
16,9
l
m 2
2,8
73
kW
1800
l/h
m 3 /h
3,1
bar
°C
186
W
4,46
kWh/24h
bar
°C
84

Advertisement

Table of Contents
loading

This manual is also suitable for:

7200/2-2000 hv plus2013623720136239

Table of Contents