Technical Data; Fuse Tab Le - CAME RADIO COMMANDS Series Installation Manual

Universal command system
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 12
"WARNING: IMPROPER INSTALLATION MAY RESULT IN SERIOUS HARM. PLEASE FOLLOW ALL INSTALLATION INSTRUCTIONS"
"THIS MANUAL IS INTENDED ONLY FOR PROFESSIONAL INSTALLERS OR OTHER COMPETENT INDIVIDUALS"
Legend of symbols
This symbol shows parts which must be read with care.
This symbol means the parts which describe safety issues.
This symbol tells you what to tell the end-user.
2 Conditions of use
2.1 Intended use
The complete TRA04 system is for commanding 230 V AC mono-phase automated operators
Any installation and use other than that specified in this manual is forbidden.
2.2 Application settings
The overall power load of the connected motor must not exceed 500W.
3 Reference standards
Came Cancelli Automatici employs an ISO 9001 certified quality management system and an ISO 14001 environmental
management system. Came only engineers and manufactures in Italy.
This product is compliant with: see statement of compliance.
4 Description
Engineered and built entirely by Came Cancelli Automatici
S.p.A.
The TRA04 kit includes:
-1 ZR24: control panel;
-1 AF43S: snap-in radio card;
-1 TOP432NA: two-channel radio transmitter.
The two-channel radio transmitter can be used to command
rolling shutter, industrial shutters and retracting awning
operators.
The card is powered by 230 V AC on terminals L1 and L2, and
should be input protected by a 5 A fuse, while the 24 V - low
voltage accessories - are protected by a 1 A fuse.
Warning! The overall power of the 24 V accessories must not
exceed 5 W.
All connections are protected by quick fuses, see table.
The card provides and controls the following functions:
- automatic closing after an opening command;
- maintained action command.
The available command modes are:
- opening/closing;
- open-stop-close-stop;
- total stop.
The photocells, after detecting an obstacle, may trigger:
- the reopening of the closing gate;
- a total stop.
Special trimmers regulate:
- the working time for automatic closing;
- the working time.
"IMPORTANT INSTALLATION SAFETY INSTRUCTIONS"
You can also connect:
- courtesy - lamp lighting the parking area for opening/
closing cycle.
TE CHNI CAL DATA
line voltage 230 V
Maximum allowed power load 500 W
power draw when idle 15 mA
maximum power for 24 V accessories 5 W
circuit insulation class
container material ABS
container protection rating IP54
working temperature -20 / +55°C

FUSE TAB LE

to protect: fuses for:
Electronic board (line)
Accessories
A 5
1 A