DV Power TRT30C Manual

Three-phase transformer, turns-ratio test instrument
Hide thumbs Also See for TRT30C:

Advertisement

Quick Links

TRT30C
THREE-PHASE TRANSFORMER
TURNS-RATIO TEST INSTRUMENT
Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TRT30C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DV Power TRT30C

  • Page 1 TRT30C THREE-PHASE TRANSFORMER TURNS-RATIO TEST INSTRUMENT Manual...
  • Page 2: Table Of Contents

    Description ............................. 7 2.1 Front Panel Components ........................7 Getting Started ............................9 3.1 Connecting the TRT30C to a Test Object ................... 9 3.2 Setting the Measurement Parameters ....................10 Error Messages ............................ 13 4.1 Error Message “Excitation current too high”..................13 4.2 Error Message “Turns ratio too low”...
  • Page 3: Introduction

    1.1.2 Terms of Use • The TRT30C shall be used only if it is in good technical condition. Its use shall be in accordance with local safety and industrial regulations. Adequate precautions must be taken to avoid any risks related to high voltages associated with this equipment and nearby objects.
  • Page 4: Orderly Practices And Procedures

    Hazardous voltages exist on the terminals of the TRT30C when the “Red” LED is lit. Never assume that the connections are safe even if this LED is off. Switch off and unplug the TRT30C before touching the connections, particularly if a fault is suspected.
  • Page 5: Power Supply

    (e.g., L1-L2; A-B). However, the voltage must not exceed 264 V AC. Please refer to the section “Technical Data”. • The TRT30C should be positioned in such a way that it is possible to safely disconnect it from the power supply at any moment. WARNING / AVERTISSEMENT This is a class A product.
  • Page 6 Three induced voltages at the transformer’s secondary side are measured. Please note that any uses of the TRT30C other than the ones described in this Manual are considered improper and will void the device warranty.
  • Page 7: Description

    Connect the TRT30C to the mains power supply with a power cord. Power switch – Double pole switch • I In this position, the TRT30C is connected to the mains power supply. • 0 In this position, the TRT30C is separated from the mains power supply.
  • Page 8 The TRT30C is equipped with an USB serial interface to connect to an external computer if required. Flash Drive The TRT30C is equipped with a USB flash drive connector to save the test results to the flash drive for additional analysis if desired. 7. TC Control TC Connector Output for the remote control of the transformer tap changer.
  • Page 9: Getting Started

    • The transformer is completely de-energized. • The TRT30C itself should be properly grounded. To do this, the grounding screw on the top of the TRT30C should be connected to PE using the provided grounding cable. Note: Always connect measuring cables to the TRT30C first and then to the test object terminals.
  • Page 10: Setting The Measurement Parameters

    ENTER 1. If the vector group is selected, the TRT30C will perform both the true three-phase test by applying true three-phase test voltage and the phase by phase test by applying single phase test voltages to all phases in turn.
  • Page 11 Low Voltage Tap Changer position If the name plate voltages are not entered, the TRT30C will perform the test and display the results, but it will not calculate or display the turns ratio deviation. After the name plate voltages and tap changer position(s) are entered, press to confirm selection.
  • Page 12 50 Hz or 60 Hz. The frequency of the output voltage is the same as the frequency of the power supply of the TRT30C. In case the TRT30C is connected to a DC power supply, the user has to choose the frequency of the output voltage to be either 50 Hz or 60 Hz.
  • Page 13: Error Messages

    "Turns ratio too low’’ 4.3 Error Message “Malfunction” In the case of an internal error, the TRT30C will display the massage “Malfunction”. In this case, the TRT30C device should be restarted. If the error occurs repeatedly, please contact the DV P...
  • Page 14: Error Message "Error Printer

    TRT30C Error Messages 4.4 Error Message “Error printer” The message “Error printer” is displayed if the hardware error concerns the printer. In this case, please Support Team (refer to the section ”Manufacturer Contact Information”). contact DV P OWER This message is also displayed if the user tries to print the results from the device which has no built-in thermal printer installed.
  • Page 15: Error Message "Emergency Stop

    4.9 Error Message “Connections” The Error message “Connections” is displayed if the H or X cables are not connected properly to the TRT30C. There are also green LED lights near the connectors which light up to indicate that these connectors are connected properly.
  • Page 16: Technical Data

    TRT30C Technical Data 5 Technical Data 5.1 Mains Power Supply - Connection: According to IEC/EN60320-1; UL498, CSA 22.2 90 – 264 V AC - Voltage: 50 – 60 Hz - Frequency: - Input power: 200 VA - Fuse: 2 A / 250 V, type F, but not user replaceable 5.2 Output data...
  • Page 17: Applicable Standards

    TRT30C Technical Data 5.6 Applicable Standards - Installation/overvoltage category: - Pollution degree: - Safety LVD 2006/95/EC (CE Conform) Standard EN 61010-1:2001 - EMC Directive 2004/108/EC (CE Conform) Standard EN 61326-1:2006 M-T030CN-203-EN...
  • Page 18: Accessories

    TRT30C Accessories 6 Accessories Article No Included DV-Win PC software including USB cable Built-in Tap Changer Control Unit Tap Changer Control cable 5 m Mains power cable Ground (PE) cable Article No Recommended H winding test cable 5 m, three-phase connection, with TTA clamps...
  • Page 19: Manufacturer Contact Information

    TRT30C Manufacturer Contact Information Manufacturer Contact Information BEKO OWER Box 1346, 181 25 Lidingö, Sweden Fax: + 46 8 731 77 99 E-Mail: support@dv-power.com Website: http://www.dv-power.com M-T030CN-203-EN...

Table of Contents