Specifications

Item
Specifications
Measurement range
Temp.
Humid.
Ouput signal
Temp.
Humid.
Sensing accuracy
Temp.
Humid.
Time constant
Temp.
(at air velocity 2 m/s)
Humid.
Environmental
Temp.
conditions
Humid.
Air velocity Extreme operating conditions: 0 to 15 m/s
Power supply
24 V AC +10/-15 % (50/60 Hz), 24 V DC +/- 10 % (only for HTY、HYseries)
Power consumption
0.2 VA
150 mW
1.0 VA
800 mW
Dielectric strength
500 V AC less than 1 mA of leak for 1 minute
Insulation resistance
500 V DC min. 20 MΩ
Vibration resistance
9.8 m/s² (10 to 150 Hz)
Protection
Housing IP54 (when splash-proof connectors and designated multi-core cables are used or when a
designated conduit is used)
The head of TY series is IP24
Installation
Duct, air chamber, ventilated case for meteological instruments (with special bracket)
Wiring
Terminal block connection
Material
Housing:
Filter cap:
Weight
Approx. 240 g (7803 series) Approx. 210 g (7813 series)
Accessories
None
Order separatly
83157235-001
83157240-004
83157240-009
83104098-004
83104098-003
DY8000A1001
DY3002A1005
Order separately for
83162945-003
maintenance
HTY78*3/HY78*3 series have passed the following tests:
EN50081-1/1992 (EN55011/1998 group 1, class B)
EN50082-1/1997 (EN61000-4-2, EN61000-4-3, ENV50204, EN61000-4-4, EN61000-4-5, EN61000-4-6,
EN61000-4-11)
-20 to 60 °C
0 to 100 % RH (-5 to 55 °C)
100 Ω / 0 °C
1-5 V DC (linear to 0 to 100 % RH) (output impedance: min. 10 kΩ)
0-10 V DC (linear to 0 to 100 % RH) (output impedance: min. 10 kΩ)
4-20 mA DC (linear to 0 to 100 % RH) (maximum permissible load 300 Ω)
+/- 0.3 °C (at conditions of -20 to 60 °C)
+/- 3 % RH (at conditions of 30 to 70 % RH 25 °C)
+/- 5 % RH (at conditions of 20 to 80 % RH 15 to 35 °C)
TY series
max. 1 min.
HTY, HY series
max. 4 min.
Max. 1 min
Rated operating conditions:
Extreme operating conditions: -20 to 60 °C
Storage conditions:
Rated operating condtions:
Extreme operating condtions: -20 to 60 °C
Storage conditions:
(at conditions of 24 V AC、HTY, HY series 1-5 V, 0-10 V output model)
(at conditions of 24 V DC、HTY, HY series 1-5 V, 0-10 V output model)
(at conditions of 24 V AC、HTY, HY series 4-20 mA output model)
(at conditions of 24 V DC、HTY, HY series 4-20 mA output model)
GF20 % Polycarbonate mixed resin, gray (equivalent to DIC-651)
Denatured PPE resin, gray (equivalent to DIC-651)
Mounting bracket
Conduit mounting set (for HTY, HY series、applicable cable outer diameter 11 to 14 φ)
Conduit mounting set (for TY series、applicable cable outer diameter 9.4 to 11 φ)
Seal connector (for HTY, HY series、applicable cable outer diameter 10.5 to 14.5 φ)
Seal connector (for TY series、applicable cable outer diameter 8.5 to 12.5 φ)
Sensor shield for outdoor
Ventilated case mounting bracket (L shape metal)
Filter set
-20 to 60 °C
0 to 100 % RH (non-condensing)
0 to 100 % RH (non-condensing)
-30 to 70 °C
5 to 95 % RH (non-condensing)
-5 to 55 °C
10 to 100 % RH (non-condensing)
0 to 100 % RH (non-condensing)
-30 to 70 °C
5 to 95 % RH (non-condensing)
3