Bamo BAMOPHOX 436 E Instruction Manual

Turbidity monitor and controller

Advertisement

Quick Links

B B
A A
M M
O O
P P
H H
O O
X X
4 4
3 3
6 6
E E
- -
M M
B B
A A
M M
O O
P P
H H
O O
X X
4 4
3 3
6 6
E E
- -
M M
Turbidity monitor and controller
INSTRUCTION MANUAL
INSTRUCTION MANUAL
MES
Turbidity monitor and controller
MESURES
BAMOPHOX 436
22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL
436-01
Tél : (+33) 01 30 25 83 20 - Web : www.bamo.fr
/1
05-06-2007
436 M1 01 C
Fax : (+33) 01 34 10 16 05 - E-mail : info@bamo.fr

Advertisement

Table of Contents
loading

Summary of Contents for Bamo BAMOPHOX 436 E

  • Page 1: Adjusting Threshold

    BAMOPHOX 436 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL 436-01 Tél : (+33) 01 30 25 83 20 - Web : www.bamo.fr 05-06-2007 436 M1 01 C Fax : (+33) 01 34 10 16 05 - E-mail : info@bamo.fr...
  • Page 2: Table Of Contents

    Turbidity monitor and controller BAMOPHOX 436 E & M (Technical information and Manual for LOGGER /RS422 version are on a specific document) Table of contents 1. TECHNICAL SPECIFICATIONS Page 3 2. CAUTION 3. DIMENSIONS 4. WIRING 5. FRONT PANEL SCROLLING MENU...
  • Page 3: Technical Specifications

    1. TECHNICAL FEATURES Displayed parameters: Measurement values of Turbidity - Configuration Menu - Temperature value Display: Back lighted - 2 lines of 16 alphanumerical characters ; 9,2 mm high Indication: LED alarms status Configuration: 8 push buttons keyboard on front face - Keyword protected Units: NTU, FAU, mg/L, g/L, FNU Scale...
  • Page 4: Wiring

    4. WIRING PANEL MOUNTING OPTION: LOGGER & RS 422 Measurement input WALL MOUNTING OPTION: LOGGER (access by the upper cover) & RS 422 Page 436 M1 01 C...
  • Page 5 Screwing terminals + mA ouput / measurement - mA ouput / measurement - mA ouput / temperature + mA ouput / temperature + 24 V To switch the regulation on stand-by - 24 V - 24 V Power supply = 20 mA + 24 V Pt 100 Ω...
  • Page 6 Screwing terminals + mA ouput / measurement - mA ouput / measurement - mA ouput / temperature + mA ouput / temperature + 24 V To switch the regulation on stand-by - 24 V - 24 V Power supply = 20 mA + 24 V Pt 100 Ω...
  • Page 7: Front Panel

    5. FRONT PANEL S1, S2, S3, and S4 2 lines /16 alphanumeric characters indicate relays status: 9.22 mm high - Back lighted LED lighting = contact ON LED OFF = contact OFF LED flashing = Timer in use Key “A” To display the parameters of upper line.
  • Page 8: Scrolling Menu

    SCROLLING MENU Display the turbidity value MENU ABOUT BAMOPHOX To consult serial number, instrument type MENU CONSULTATION / MODIFICATION MENU SCALE PARAMETERS MENU ADUST ALARM 1 MENU ADUST ALARM 2 MENU ADUST ALARM 3 MENU OUTPUT mA TURB MENU OUTPUT mA TEMP MENU FORCED DISPLAY MENU...
  • Page 9: Measurement Parameters

    MENU SCALE PARAMETERS ADJUST ALARM 1 page 10 ENTER UNIT Choose between NTU FAU, mg/l, g/l, FNU ENTER x-x,xxx NTU Decimal point selection ENTER SCALE ENTER MINI : 00,00 NTU Minimal range value ENTER MAXI : 00,00 NTU Maximal range value ENTER TRANSMITTER ENTER...
  • Page 10 ADJUST ALARM 1 MENU ADJUST ALARM 2 ENTER ALARM 1 ON/OFF ENTER ALARM 1 MEASURE/TEMP MEASURE= Threshold against pH/mV measured value TEMP.= Threshold against temperature measured value ENTER ALARM 1 LOW/HIGH HIGH= Contact closes when value goes over the limit LOW= Contact closes when the value goes under the limit ENTER ON 0000 NTU / °C...
  • Page 11: Analog Output 4-20 Ma For Turbidity

    ADJUST ALARM 3 MENU OUTPUT mA TURB ENTER ALARM 3 ON/OFF ENTER ALARM 3 MEASURE/TEMP MEASURE= Threshold against pH/mV measured value TEMP.= Threshold against temperature measured value ENTER ALARM 3 LOW/HIGH HIGH= Contact closes when value goes over the limit LOW= Contact closes when the value goes under the limit ENTER ON 0000 NTU / °C...
  • Page 12: Analogue Output 4-20 Ma For Temperature

    OUTPUT mA TEMP. MENU MARCHE FORCEE Caution: If PID regulation is active, this step menu would not appears ENTER HIGHER 0000 NTU Value corresponding to 20,00 mA ENTER LOWER 0000 NTU Value corresponding to 00,00 mA or 04,00 mA ENTER OUTPUT 4/20 mA / 0/20 mA Output type ENTER...

This manual is also suitable for:

Bamophox 436 m436-02

Table of Contents