Download Print this page

Voxx Electronics Prestige APSSEC Quick Installation Manual page 2

Security w/keyless entry

Advertisement

APSSEC
Security w/Keyless Entry
Quick Installation Guide
For Complete Installation Guide and Technical Support
Please Visit
www.voxxuniversity.com
Or Call
1-800-225-6074
REV. B
2020 Voxx Electronics. All Rights Reserved.
Notifications
Alarm
When the alarm is triggered the system will provide feedback to the user. Upon disarm,
the system will beep 4x and flash the LED to indicate the Alarm Trigger Zone.
1 Shock
2 Trunk/Hood
3 Door
Chirp Delete
System ARM/DISARM chirps can be toggled ON or OFF without entering the Feature
Bank programming.
1.
Turn the ignition key ON/OFF.
2.
Press and release the valet button three (3) times.
The system will respond with one (1) chirp for ON and two (2) Chirps for OFF. This
feature will not affect alarm trigger or programming.
User Programmable LED
System LED notifications can be turned ON or OFF without entering Feature Bank
programming.
1.
Turn the ignition key ON/OFF, ON/OFF.
2.
Press and hold valet button for five (5) seconds.
The LED will flash one (1) time for ON, two (2) times for OFF. This feature will not affect
LED flash during programming.
Shock Sensor
The shock sensor should be mounted to a solid surface in the center of the vehicle.
Once mounted the shock sensor will require adjustment.
To increase sensitivity: Turn adjustment dial clockwise.
To decrease sensitivity: Turn adjustment dial counter clockwise.
To test sensitivity, strike the vehicle with an open palm. Adjust the dial to provide
coverage to as much of the vehicle as possible.
Factory Keyless Upgrade
The APSSEC can be used without transmitters as a Factory Keyless Alarm Upgrade. Arm /
Disarm 1 inputs will be connected to the Driver Door Lock Motor. Arm / Disarm 2 inputs
will be connected to the Passenger Door Lock Motor and / or the Lock Switch. The control
polarity, by default, will be detected automatically upon power up. The Control polarity can
also be manually configured using Feature Bank 2, Features 18-21.
Note: If this feature is supported by FLCAN Arm / Disarm Wires are not required for install.
The Trunk Shunt input will be used if the vehicle is equipped with a factory power trunk
/ hatch release. If equipped, connect the Trunk Shunt input to the factory trunk release
trigger wire. The control polarity, by default, will be detected automatically upon power up.
The control polarity can also be manually configured using Feature Bank 2, Feature 22.
Remote Programming
The APSSEC does not include an RF remote kit. The RF remote kit Includes two (2) remotes,
one (1) antenna, and one (1) cable. When added, remotes must be programmed to
the system. Remote Programming is located in Feature Bank 1. To enter Remote Auto
Programming:
1.
Turn the ignition key to ON.
2.
Press and release the valet button three (3) times. System will beep and flash the
parking lights one (1) time.
Press the lock button on each remote. The system will beep one (1) time to indicate the
remote has been programmed. If programming one (1) button remotes, press the Start
button. Only primary remote functions are auto programmed. This Includes Lock, Unlock,
and Trunk/Start.
If using AUX output control, you must manually program the AUX output channels to
the remote. Please see the complete installation guide for manual remote programming
instruction.
Note: If programming 2-Way remotes, wait for the remote to beep before programming
additional remotes. This beep is confirmation that a 2-Way response has been received
from the main module.
Feature Programming
The APSSEC Feature Banks can be programmed by using the valet button and the OEM or
Prestige remote. To enter Feature Bank programming:
1.
Turn the ignition key to ON.
2.
Press and release the valet button three (3) times. System will beep and flash lights
one (1) time for Feature Bank 1, Remote Programming.
3.
Cycle ignition key OFF/ON. System will beep and flash lights two (2) times for
Feature Bank 2.
4.
Press valet button to cycle features. LED will flash to display feature number.
5.
Press lock button to cycle options. System will beep to indicate option number.
To exit Programming cycle ignition key OFF and wait ten (10) seconds. The System will also
automatically exit programming after sixty (60) seconds of no activity.
Dome Delay Programming
This system can be programmed to ignore the vehicle's theater dimming dome light. This
feature will be used when connecting the door trigger input to the dome light circuit for
alarm trigger. Note: Vehicle windows should be open to prevent accidental locking of keys
in the vehicle.
Start with all doors closed and the vehicle dome light off.
1.
Press Lock, Unlock, Lock, Unlock, Lock, Unlock, Lock. LED will light solid.
2.
Open and close the driver door.
The system will monitor the dome light circuit. When the dome light turns off the system
will set the delay time and add an additional two (2) seconds.
Dome Delay Reset
1. Key ON/OFF, ON/OFF, ON/OFF.
2. Press and hold valet button for five (5) seconds.
The system will beep one (1) time to indicate reset is complete.
The Feature Bank below can also be programmed using the FlashLogic Weblink or Weblink Mobile.
Please visit www.FlashLogic.com for more detail.
Features
1 Chirp
2 Chirp
1 Lock / Unlock Func�on
500ms
3.5sec
2 Igni�on Lock
OFF
ON
3 Igni�on Unlock
OFF
Unlock All
4 Exterior Illumina�on
OFF
With Arm
5 Auto Relock
OFF
Auto Lock Only
OFF
6 Auto Arming / Locking
Auto Arm Only
7 No�fica�on Sound
Both
Siren
8 Horn Timing
16ms
30ms
9 Valet Override Method
Valet
Custom Code
10 Driver Priority Unlock
OFF
ON
11 Silent Choice
OFF
From Transmi�er
12 Security Profile
All On
Doors Off
13 Door Trigger Input
Negative
Posi�ve
14 Park Light / Trunk Swap
OFF
ON
15 Data Port Protocol
ADS
DBI
16 1 or 2 Wire Disarm
2 Wire
1 Wire
17 Disarm Input
120ms Dr OR Pass
80ms Dr OR Pass
18 Arm 1 Input
Auto Detect
Posi�ve
Auto Detect
19 Disarm 1 Input
Posi�ve
20 Arm 2 Input
Auto Detect
Posi�ve
21 Disarm 2 Input
Auto Detect
Posi�ve
22 Trunk Shunt Input
Auto Detect
Posi�ve
23 Dome Light Delay Timer
OFF / Program
15sec
24 Alarm Trigger Length
30sec
45sec
The default data port protocol of this system is ADS. When flashing the FLCAN, or other integration module, be sure to choose iDatalink 2-Way as the installation method.
This module will also support DBI. This will require programming Feature Bank 2, Feature 15 to DBI. For Technical Support Visit www.voxxuniversity.com or Call 1-800-225-6074.
Negative Output Control (NOC)
Negative output control allows any NOC to be programmed for any one of the options
below. This feature is accessible via FlashLogic Weblink or Weblink Mobile.
Lock Output
Ground While Armed
(GWA)
Unlock Output
Ground While Disarmed
(GWD)
2nd Unlock Output
Ch. 3 ALT Output
Trunk Output
Ch. 4 AUX Output
Dome Light Output
Ch. 5 AUX Output
Head Light Output
Ch. 6 AUX Output
Horn Output
Ch. 7 AUX Output
LED Output
AUX Output Control
Any AUX output can be configured using the AUX Control Menu. This feature is only
accessible via FlashLogic Weblink or Weblink Mobile.
1 Second Pulse
20 Second Pulse
5 Second Pulse
30 Second Pulse
10 Second Pulse
Push & Hold
15 Second Pulse
Latch ON/OFF
PIC Input Control
Programmable Input Control allows any PIC be configured to one of the options listed
below. This feature is accessible via FlashLogic Weblink or Weblink Mobile.
Door Trigger
Instant Trigger
N.C. Door Trigger
Pre-Warn Shock Trigger
Hood Trigger
Fill Shock Trigger
Trunk Trigger
Op�ons
3 Chirp
4 Chirp
5 Chirp
500ms L, DBL UL
DBL L, 500ms UL
DBL L, DBL UL
Unlock Driver
With Disarm
With Arm & Disarm
Auto Lock & Arm
Auto Lock & Arm
Horn
40ms
50ms
10ms
Stand Alone Valet
OEM Style
Hood/trunk Off
All Off
All On w/ OEM RS
120ms, UL & Light
80ms, UL & Light
Nega�ve
Nega�ve
Nega�ve
Nega�ve
Nega�ve
30sec
45sec
60sec
60sec
90sec
120sec
Important Update:
Data Protocol Selection
The default data port protocol of this model is ADS (iDatalink 2-Way). This model is
capable of detecting the correct data port protocol (ADS or DBI) and automatically
configuring Feature Bank 2; Feature 18. To initialize the detection procedure:
1.
Press and hold the valet button.
2.
Cycle the vehicle's Ignition ON/OFF two (2) times.
3.
Release the valet button.
The system will automatically detect and set the correct data port protocol, ADS or DBI.
Note: This feature is only available on module firmware v2.0 or higher.
Notes
6 Chirp
500ms L, 350ms UL
120sec

Advertisement

loading