4.
Unbolt the four screws of the lid of the connection
terminal box and remove the lid. Take out the
aluminium rail afterwards.
5.
To close the casing, reverse this procedure.
5.2
Insert the PM5-SA4 plug-in module
1. Use plug-in connector 1 (on the left) for the
installation of the PM5-SA4 plug-in module.
2. Dismantle the cable (or cables) on the required
length inside the casing and insert it (them) into the
casing through one or more cable glands.
3. Now connect the cable ends to the connection
4. Insert the PM5-SA4 plug-in module carefully into the
PM5-SA4 Converter 4-20mA – User Manual
IMPORTANT NOTICE!
In order to minimize the influence of possible
inductive disturbances, we recommend to
use cables with twisted cable pairs for each
channel.
terminals of the PM5-SA4 plug-in module. The digits
1 to 4 indicate the channel numbers which you can
later select in the configuration menu.
plug-in connector 1 (on the left).
HAZARD!
Improper positioning
Improper (inaccurate) positioning of the plug-
in module and applying too strong forces
may bent or even break the contact pins of
the plug-in connector.
Potential consequence:
of the plug-in connector, need for factory
repair service.
Take care for the correct and accurate
position of the plug-in module and do not
apply too strong forces.
Irreparable damage
3