Device description
Environmental conditions - mechanical
Emission test
Radiated emissions - enclosure ports (30 Mhz
to 1 GHz), CISPR 16-2-3/ EN 55016-2-3
Immunity test
Electrostatic discharge, IEC 61000-4-2
Radiated radio-frequency electromagnetic
field, IEC 61000-4-3
Radiated radio-frequency electromagnetic
field, IEC 61000-4-3
Power frequency magnetic field,
IEC 61000-4-8
Impulse magnetic field, IEC 61000-4-9
4.5

Connections

4.5.1

Power connector (X1)

The EDS500 devices are equipped with a wide range power supply for voltages between 24
and 60 Volts DC (power consumption see device label). The connector is a 3-pin Phoenix plug
with screw terminals.
The power lead has to be sufficiently fused and a manual interrupter for the power supply
has to be installed (emergency switch). For the full effect of the overvoltage protection the
functional earthing has to be connected and the hat rail has to be earthed.
The installation has to comply with national installation standards. An external, optional
power supply can be used for connection to 230 VAC.
Power supply input (X1)
Operating voltage
Power consumption (typical)
Current demand (peak)
Plug type
Reverse polarity protection
Circuit classification
Galvanic isolation
Overvoltage protection
Electrical fast transient / Burst, IEC 61000-4-4 4 kV (level 4), criterion A
Surge 1.2/50 µs, IEC 61000-4-5
Conducted, common mode disturbances
in the frequency range 0 Hz to 150 kHz,
IEC 61000-4-16
1KGT151042 V000 1
100 m/s², 16 ms
1000 shocks per direction
IEC 60255-21-2 class 1
EN 55022/ CISPR 22 class A
8 kV air / 6 kV contact (level 3), criterion A
10 V/m (level 3), criterion A
80 MHz to 1 GHz: 20 V/m (level x), criterion A
1 GHz to 2.7 GHz: 10 V/m (level 3), criterion A
100 A/m (level 5), criterion A
300 A/m (level 4), criterion A
24...60 V DC -15%...+20%
specific for device, see device label
specific for device, see device label
Phoenix Contact MSTBT 2.5/3-ST
yes
ES2 (acc. to IEC 62368-1)
1.5 kV isolation voltage
±4 kV line to earth, ±2 kV line to line
4 kV line to earth, 2 kV line to line (level 4), cri-
terion A
30 V continuous disturbance/ 300 V short
duration disturbance (level 4), criterion A
Connections
23