Modem 1200 baud 500FSD10
EDS500 series - FSK modems
Application, characteristics and technical data have to
be taken from the hardware data sheet:
500FSD10 Data sheet 1KGT150982
Operation
The 500FSD10 modem is a CCITT V.23 modem for
snap-in DIN-rail mounting. V.23 operates with the
frequency shift keying method (FSK). The modem can
operate in two- and four-wire connection. The mode of
operation is set by means of a twelve-fold DIP-switch.
Connections
Power connector for compact devices (X1)
The EDS500 series devices are equipped with a wide
range power supply for voltages between 24 and
60 Volts (power consumption see device label). The
connector is a 3-pin Phoenix plug with screw terminals.
Pin allocation power supply
1
Due to the internal overvoltage protection,
interrupt any connection to ground of the device
for the time of the measurement before you carry
out isolation measurement. This includes the
earthing of the hat rail as well as all shields of all
transmission lines and supply feedings. RJ-12 plugs
or RJ-45 plugs can establish earthing via the shield.
Serial Interface to DTE (X2)
The RJ-45 connector X2 forms an RS-232-D interface. If
the modem is connected to a terminal unit, an adapter
cable has to be used which connects the pin pairs.
Pin allocation serial interface DTE (RJ-45)
Pin
Signal
2
3
1
VIN+ (24-60 VDC)
2
Shield connected to functional earth
3
VIN-
A D V I C E
RS-232-D
Pin
Signal
V.24
1
DSR M1
8
1
2
DCD M5
Pin allocation serial interface DTE (RJ-45)
Interface to transmission line (X3)
In two-wire mode X3-1 and X3-2 form terminal NF1
which is used for transmission and reception.
In four-wire mode X3-1 and X3-2 form the transmitter
terminal NF1 and X3-3 and X3-4 form the receiver pair
NF2.
NF terminals
2-wire
4-wire
Pin allocation transmission line interface (X3)
Signaling
LED
Power
RTS
Signal
Direction
V.28
107
output
109
output
3
DTR S1
4
GND
5
RxD C2
6
TxD D1
7
CTS M2
8
RTS S2
transmit
NF1: X3-1 and X3-2
NF1: X3-1 and X3-2
Pin
Signal
4
3
2
1
1
NF1a
2
NF1b
3
NF2a
4
NF2b
Description Function
Voltage
Supply
Request to
send
108.2
input
GND
-
104
output
103
input
106
output
105
input
receive
NF1: X3-1 and X3-2
NF2: X3-3 and X3-4
off
Device is without
power supply
green
Power supply
switched on
off
DTE does not
send
green
DTE requests
to send via the
modem

Advertisement

loading

Summary of Contents for ABB 500FSD10

  • Page 1 500FSD10 Data sheet 1KGT150982 RxD C2 output TxD D1 input Operation The 500FSD10 modem is a CCITT V.23 modem for CTS M2 output snap-in DIN-rail mounting. V.23 operates with the RTS S2 input frequency shift keying method (FSK). The modem can operate in two- and four-wire connection.
  • Page 2: Description Function

    Short-circuit current < 8A • position at a time. If the 500FSD10 is to be terminated with the line WARNING impedance, the DIP switches T-T and T-R need to be switched to 'on'. This is usually the case at both ends No plug shall be freely accessible in normal of the line.
  • Page 3: Installation

    (DTE) by connecting modem. X1-2 has to be connected to functional earth. X2 of the 500FSD10 to the serial interface of the DTE by a shielded serial cable, e.g. 500CAB08, 500CAB09. Terminal X1-1 is connected to the positive terminal and...
  • Page 4 Figure 3: 500FSD10 Label Figure 2: 500FSD10 Front plate Figure 1: 560FSD10 1 2 3 Connect DIN-rail to Protection earth 1 2 3 4 Figure 4: Schematic installation drawing NF2a NF2b NF1a NF1b Figure 5: Communication line connection by LF transformer (two-wire connection)
  • Page 5 NF2a NF2b Receive NF1a NF1b LF signal transformer Transmit Figure 6: Communication line connection by LF transformer (four-wire connection)
  • Page 6 Tel. +49 621 381-3000 particulars shall prevail. ABB AG does not or in parts – is forbidden without prior written accept any responsibility whatsoever consent of ABB AG. Copyright© 2019 ABB AG for potential errors or possible lack of All rights reserved www.abb.com/remote-terminal-units...