Kenwood NXR-700H Service Manual page 122

Vhf digital base-repeater
Table of Contents

Advertisement

NXR-700H
Item
Condition
24. DQT
1) Channel: 3 (Center)
Deviation
Wide/Narrow: Analog Wide
Connect the deviation meter
to the TX ANT end via the
ATT.
Deviation meter setting
HPF: OFF
LPF: 3kHz
De-emp: OFF
Detector: Peak hold
2) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
25. CW ID
1) Channel: 3 (Center)
Deviation
Wide/Narrow: Analog Wide
Connect the deviation meter
to the TX ANT end via the
ATT.
Deviation meter setting
HPF: OFF
LPF: 15kHz
De-emp: OFF
Detector: +peak, –peak
2) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
26. Test Tone
1) Channel: 3 (Center)
Deviation
Wide/Narrow: Analog Wide
Connect the deviation meter
to the TX ANT end via the ATT.
Deviation meter setting
HPF: OFF, LPF: 15kHz
De-emp: OFF
Detector: (p-p)/2
2) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
27. DTMF
1) Channel: 3 (Center)
Deviation
Wide/Narrow: Analog Wide
Connect the deviation meter
to the TX ANT end via the ATT.
Deviation meter setting
HPF: OFF, LPF: 15kHz
De-emp: OFF
Detector: (p-p)/2
2) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
28. Courtesy
1) Channel: 3 (Center)
Tone
Wide/Narrow: Analog Wide
Deviation
Connect the deviation meter
to the TX ANT end via the ATT.
Deviation meter setting
HPF: OFF, LPF: 15kHz
De-emp: OFF
Detector: (p-p)/2
2) Channel: 3 (Center)
Wide/Narrow: Analog Narrow
122
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Deviation
Rear
TX ANT
meter
Deviation
Rear
TX ANT
meter
Deviation
Rear
TX ANT
meter
Deviation
Rear
TX ANT
meter
Deviation
Rear
TX ANT
meter
Adjustment
Parts
Method
PC
±0.75kHz
±0.05kHz
ADJ
Connect the deviation meter
to the TX ANT end via the
ATT.
±0.35kHz
±0.05kHz
PC
±2.00kHz
±0.05kHz
ADJ
Connect the deviation meter
to the TX ANT end via the
ATT.
±1.00kHz
±0.05kHz
PC
±3.00kHz
±0.05kHz
ADJ
Connect the deviation meter
to the TX ANT end via the
ATT.
±1.50kHz
±0.05kHz
PC
±2.85kHz
±0.05kHz
ADJ
Connect the deviation meter
to the TX ANT end via the
ATT.
±1.50kHz
±0.05kHz
PC
±1.00kHz
±0.05kHz
ADJ
Connect the deviation meter
to the TX ANT end via the
ATT.
±0.50kHz
±0.05kHz
Specifi cations / Remarks

Advertisement

Table of Contents
loading

Table of Contents