Further Information - Racer UNO Instructions For Use Manual

Salt chlorinator
Table of Contents

Advertisement

Available languages

Available languages

IMMEDIATE
AUTOMATIC ACTION
MESSAGE
DISPLAYED
Stopping
production
A4
Yes
A7
No
AL
No
CA
No

3.9. Further information

Menu
Sub-menu
cm
Sw
pw
Stopping
FAULT DETECTED
pH
regulation
No
Cell problem.
Yes
pH corrector container empty.
Series of 5 unsuccessful attempts to
Yes
correct the pH.
Yes
pH probe incorrectly calibrated.
Successive display
2 digits, then 2 other digits
2 digits, then 2 other digits
CHECKS AND REMEDIES
• Check that the cell is not scaled.
• Inspect and adjust if necessary the
inversion frequency of the current
supplying the cell.
• Check
that
the
connections to the terminals of the
cell are sufficiently tight and not
oxidised.
• Check that the cell's power cable is
in good condition.
• Check that the cell's power cable
connector is correctly connected to
the electronics unit.
• As a last resort, replace the cell.
Replace the pH corrector container.
• Ensure the pH corrector container is
not empty.
• Carry out a manual injection.
• Check the condition of the filter
with
ballast
and
connector.
• Check :
- Setting the pH setpoint.
- The specification of the type of pH
corrector.
- The
specification
concentration of the pH corrector.
- The specification of the volume of
the pool.
• Carry out a calibration of the pH
probe.
Carry out a calibration of the pH
probe, by pressing and holding
Meaning
Control board program
Power card program
electrical
injection
of
the
OK
.
11