3.7.5. Calibration of the pH measurement

Menu
Ad

3.7.6. Setting the inversion frequency of the current supplying the cell

I
Current inversion aims to prevent scale deposits on the cell. Current inversion must be set following the
table below in order to ensure that the cell continues to operate correctly in the long term.
Water hardness (°f)
Inversion frequency (h)
Menu
In

3.7.7. Setting the production setpoint

Specific instructions
Directly select a value using the
(no confirmation required).

3.7.8. Setting the pH setpoint

Menu
Se

3.7.9. Boost mode

Boost mode :
- sets the production setpoint up to 125 %, for a fixed period.
- can be manually stopped at any time.
- can be used when chlorine is urgently needed.
I
Boost mode cannot replace a conventional shock treatment in cases of water not fit for bathing.
• If the Boost mode is restarted manually while it is already running, the Boost mode resets for the duration
displayed.
• Boost mode cannot be switched on if an alarm has been triggered. After having resolved and dismissed this alarm,
wait a few moments in order to be able to activate the Boost mode.
• When the Boost mode ends or is manually stopped, production continues according to the initial setpoint.
• Boost mode continues after powering off the electronics unit.
Operation with a cover sensor :
• Boost mode cannot be switched on with the cover shut.
• If the cover is closed with Boost mode switched on, Boost mode automatically stops.
Possible
Menu
settings
• 12 (h)
Bo
• 24 (h)
Possible settings
From 6.5 to 7.5 in increments of 0.1.
0 to 5
5 to 12
16
Possible settings
From 02 to 24 (h), in increments of 1.
buttons
Possible settings
From 6.8 to 7.6, in increments of 0.1.
Default
setting
Automatic as soon as the duration
24
setting is confirmed.
12 to 20
10
8
Possible settings
• From 05 to 95 (%), in increments of 5.
• 99 (%).
• OF (deactivation of the chlorinator cell).
Switching on
Default setting
7.0
20 to 40
40 to 60
6
4
Default setting
06
Default setting
Default setting
7.2
Power indicator
display
Bo
> 60
2
99
Switching off
Press on
.
7