Electrolux EUF1900AOW User Manual page 14

Hide thumbs Also See for EUF1900AOW:
Table of Contents

Advertisement

Available languages

Available languages

14
www.electrolux.com
Problem
There is too much frost
and ice.
The compressor does not
start immediately after
pressing the "FastFreeze",
or after changing the tem‐
perature.
Temperature cannot be
set.
Door is misaligned or inter‐
feres with ventilation grill.
The temperature in the ap‐
pliance is too low/too high.
Possible cause
The door is not closed cor‐
rectly.
The FastFreeze function is
switched on.
The door is not closed cor‐
rectly or the gasket is de‐
formed/dirty.
The water drainage plug is
not correctly positioned.
Food products are not
wrapped properly.
Temperature is set incor‐
rectly.
This is normal, no error
has occurred.
The "FastFreeze function"
is switched on.
The appliance is not level‐
led.
The temperature regulator
is not set correctly.
The door is not closed cor‐
rectly.
The food products' temper‐
ature is too high.
Many food products are
stored at the same time.
The thickness of the frost
is greater than 4-5 mm.
The door has been opened
often.
Solution
Refer to "Closing the door".
Refer to "FastFreeze func‐
tion".
Refer to "Closing the door".
Position the water drain‐
age plug in the correct
way.
Wrap the food products
better.
Refer to "Operation" chap‐
ter.
The compressor starts af‐
ter a period of time.
Switch off "FastFreeze
function" manually, or wait
until the function resets au‐
tomatically to set the tem‐
perature. Refer to "Fast‐
Freeze function".
Refer to "Levelling".
Set a higher/lower temper‐
ature.
Refer to "Closing the door".
Let the food products tem‐
perature decrease to room
temperature before stor‐
age.
Store less food products at
the same time.
Defrost the appliance.
Open the door only if nec‐
essary.

Advertisement

Table of Contents
loading

Table of Contents