TROUBLESHOOTING: 7-WAY WITH INTERIOR LIGHTS INTERIOR LIGHTS DO NOT COME ON Step 1: Inspect the wiring and confirm that all connections are tight. Step 2: Check for a voltage greater than 10 volts to the lights, as shown. • If yes, inspect the wiring between the nosebox and the lights for defects.
Page 5
(if installed) for defects. – To check the operation of the external switch, proceed to the next step. • If the lights do not come on, replace the cover assembly. P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net...
EXTERIOR SWITCH OF INTERIOR LIGHT OPERATIONAL CHECK Step 6: Position meter to measure the resistance reading. • Press for continuity, if meter has this feature. • Place leads as shown. Press interior light switch - readings should be 0 or very low resistance. •...
• If all voltages are good: – If exterior switch is used skip to step 6. – If no exterior switch is used proceed to step 5. P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net...
Page 8
Step 5: Place the jumper between the posts. • If the lights come on and there is no external switch, replace the cover assembly. • If there is an exterior switch, proceed to the next step. Step 6: Position the meter to read resistance.
Step 3: Check for a voltage greater than 10 volts to the lights, as shown. • If yes, inspect the wiring between the nosebox and the lights for defects. • If no, continue to the next step. P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net...
Page 10
Step 4: Check for a voltage greater than 10 volts. • If yes, inspect the wiring in the nosebox for defects. • If no, continue to the next step. Step 5: Check for voltage greater than 10 volts. • If yes, replace the cover assembly.
• Place leads as shown. • Press the interior light switch. • Voltage should read 0 or a very low resistance. • If no, inspect the wiring between the nosebox and the switch for defects. P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net...
TROUBLESHOOTING: DUAL/SINGLE POLE WITH INTERIOR LIGHTS INTERIOR LIGHTS DO NOT COME ON Step1: Inspect the wiring and confirm that all connections are tight. Step 2: Turn the interior lights on by pressing the switch on the nosebox, then continue to the following steps. Step 3: Check for a voltage greater than 10 volts to the lights, as shown.
Page 13
(if installed) for defects. • To check operation of the external switch, proceed to the next section. • If the lights do not come on, replace the cover assembly. P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net...
EXTERIOR SWITCH OF INTERIOR LIGHT OPERATIONAL CHECK Step 1: Position the meter to read resistance. • Press for continuity, if the meter has this feature. • Place leads as shown. • Press the interior light switch. • Voltage should read 0 or a very low resistance.