PR electronics 2240 Manual
Hide thumbs Also See for 2240:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Displays
Programmable displays with a wide se-
lection of inputs and outputs for display of temperature,
volume and weight, etc. Feature linearisation, scaling,
and difference measurement functions for programming
via PReset software.
Ex interfaces
Interfaces
for
analogue
signals as well as HART
signals between sensors / I/P
®
converters / frequency signals and control systems in Ex
zone 0, 1 & 2 and for some modules in zone 20, 21 & 22.
Isolation
Galvanic isolators for analogue and digital
signals as well as HART
signals. A wide product range
®
with both loop-powered and universal isolators featuring
linearisation, inversion, and scaling of output signals.
Temperature
A wide selection of transmitters for DIN
form B mounting and DIN rail modules with analogue
and digital bus communication ranging from application-
specific to universal transmitters.
Universal
PC or front programmable modules with
universal options for input, output and supply. This range
offers a number of advanced features such as process
calibration, linearisation and auto-diagnosis.
and
digital
2 2 4 0
T r a n s f o r m e r
N o . 2 2 4 0 V 1 0 1 - I N ( 1 0 1 5 )
F r o m s e r . n o . 9 7 0 2 7 9 0 0 1
S I G N A L S T H E B E S T
Side 1
DK
Page 11
UK
Page 23
FR
Seite 35
DE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2240 and is the answer not in the manual?

Questions and answers

Summary of Contents for PR electronics 2240

  • Page 1 Displays Programmable displays with a wide se- lection of inputs and outputs for display of temperature, volume and weight, etc. Feature linearisation, scaling, and difference measurement functions for programming via PReset software. Ex interfaces Interfaces analogue digital signals as well as HART signals between sensors / I/P ®...
  • Page 2: Table Of Contents

    TRANSFORMATOR Type 2240 INDHOLDSFORTEGNELSE Advarsler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Sikkerhedsregler .
  • Page 3: Sikkerhedsregler

    SIGNATuRFORKLARING pR electronics A/S, Lerbakken 10, DK-8410 Rønde tlf: +45 86 37 26 77. Trekant med udråbstegn: Advarsel / krav . Hændelser der kan Installation og tilslutning af modulet skal følge landets gældende regler for instal- føre til livstruende situationer .
  • Page 4: Overensstemmelseserklæring

    I det omfang, instruktionerne i denne manual ikke nøje er overholdt, vil kunden ikke kunne rette noget krav, som ellers måtte eksistere i henhold til den indgåede salgsaftale, mod PR electronics A/S . Rønde, 12 . april 2010 Kim Rasmussen...
  • Page 5: Adskillelse Af System 2200

    Billede 2: Afmontering af knapper . MONTERING: 2240 benytter en standard 11-polet sokkel og kan monteres i alle stillinger . For bedste luftafkøling anbefales det at montere enheden i lodret stilling og at holde en mindre afstand (10 mm) til nabomoduler .
  • Page 6: Elektriske Specifikationer

    Specifikationsområde: Type Indgang udgang -20°C til +60°C 2240 115 VAC Speciel Fælles specifikationer: 230 VAC 24 VAC Isolation, test / drift ........3,75 kVAC / 250 VAC...
  • Page 7 TRANSFORMER bELASTNINGSSKEMA FOR MAx. EFFEKTuDGANG: Type 2240 CONTENTS Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Safety instructions .
  • Page 8: Warnings

    General mounting, connection and disconnection of wires . Troubleshooting the module . Repair of the module and replacement of circuit breakers must be done by pR electronics A/S only. WARNING! To keep the safety distances, modules with two built-in relays...
  • Page 9: Safety Instructions

    To the extent the instructions in this manual are not strictly observed, the custom- All modules fall under Installation Category II, Pollution Degree 1, and Insulation er cannot advance a demand against PR electronics A/S that would otherwise Class II .
  • Page 10: Declaration Of Conformity

    As manufacturer The back panel of the module is detached from the housing by way of a pR electronics A/S screwdriver as shown in picture 1 . On a module with knobs, these may have to be removed before the PCB can be Lerbakken 10 taken out as shown in picture 2 .
  • Page 11: Applications

    VNIIM, Cert . no . ......... . . See www .prelectronics .com The 2240 is for standard 11-pole socket mounting in all positions . To achieve...
  • Page 12: Order

    ORDER: LOAD DIAGRAM FOR MAx. pOWER OuTpuT Type Input Output 2240 115 VAC Special 230 VAC 24 VAC Special 12 VAC bLOCK DIAGRAM:...
  • Page 13 TRANSFORMATEuR Type 2240 SOMMAIRE Avertissements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Consignes de sécurité...
  • Page 14: Avertissements

    DIP et les cavaliers, montage général, raccordement et débranchement de fils et recherche de pannes sur le module . Seule pR electronics SARL est autorisée à réparer le module et à remplacer les fusibles. AVERTISSEMENT ! Afin de conserver les distances de sécurité, les modules à...
  • Page 15: Consignes De Sécurité

    SARL, Zac du Chêne, Activillage, 4, allée des Sorbiers, F-69673 Bron auprès de PR electronics SARL, même si cette dernière figure dans l’accord de Cedex (tél . : (0) 472 140 607) ou à PR electronics A/S, Lerbakken 10, DK-8410 vente conclu .
  • Page 16: Déclaration De Conformité

    . Lorsque vous extrayez la carte à déclare que le produit suivant : circuits imprimés, tirez sur celle-ci et évitez de tirer sur les fils (voir figure 3) . Type : 2240 Vous pouvez maintenant déplacer les commutateurs et les cavaliers . Lorsque Nom : Transformateur vous assemblez la face arrière du module et le boîtier, veuillez vérifier que les fils...
  • Page 17: Applications

    Tension secondaire (chargée) ..... . 12 Vca / 2,50 A la température ambiente et la sortie VA max . Le 2240 est livré avec un support Tension secondaire (non-chargée) .
  • Page 18: Référence De Commande

    REFERENCE DE COMMANDE : DIAGRAMME (puISSANCE MAx. EN SORTIE) : Type Entrée Sortie 2240 115 Vca A spécifier 230 Vca 24 Vca A spécifier 12 Vca SCHEMA DE pRINCIpE :...
  • Page 19 TRANSFORMATOR TYp 2240 INHALTSVERZEICHNIS Warnung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Sicherheitsregeln .
  • Page 20: Warnung

    Installation, Montage und Demontage von Leitungen . Fehlersuche im Modul . Reparaturen des Moduls und Austausch von Sicherungen dürfen nur von pR electronics A/S vorgenommen werden. WARNuNG! Zur Einhaltung der Sicherheitsabstände dürfen Module mit zwei eingebauten Relaisein heiten nicht sowohl an gefährliche und ungefährliche Spannung über die selben Relaiskontakte des...
  • Page 21: Sicherheitsregeln

    GmbH, Im Erlengrund 26, D-46149 Oberhausen, (Tel.: (0) vereinbarungen existieren können . 208 62 53 09-0) oder mit pR electronics A/S, Lerbakken 10, DK-8410 Rønde, Däne mark (Tel. : +45 86 37 26 77) Kontakt aufnehmen .
  • Page 22: Konformitätserklärung

    ZERLEGuNG DES SYSTEMS 2200 Als Hersteller bescheinigt Die hintere Abdeckplatte des Moduls wird vom Gehäuse mit Hilfe eines pR electronics A/S Schraubendre hers gelöst, wie im Abb . 1 dargestellt . Bei Modulen mit Drehknöpfen kann es notwendig werden, diese zu entfernen, Lerbakken 10 ehe man die Platine herausnehmen kann (siehe Abb .
  • Page 23: Anwendung

    VNIIM, Cert . no . ......... . . Siehe www .prelectronics .de MONTAGE: 2240 verwendet einen genormten 11-poligen Sockel und kann in allen Stellungen Eingehaltene Richtlinien: Norm: eingebaut werden .
  • Page 24: Bestellangaben

    Eingang Ausgang 2240 115 VAC Spez . 230 VAC 24 VAC Spez . 12 VAC bLOCKDIAGRAMM:...
  • Page 25 Subsidiaries PR electronics A/S tilbyder et bredt program af analoge og digitale France signalbehandlingsmoduler til industriel automation. Programmet PR electronics Sarl Zac du Chêne, Activillage sales@prelectronics.fr består af Isolatorer, Displays, Ex-barrierer, Temperaturtransmittere, 4, allée des Sorbiers tel. +33 (0) 4 72 14 06 07 Universaltransmittere mfl.

Table of Contents