Galaxy LEC Installation And Operating Instructions

Electronic ballast

Advertisement

Quick Links

LEC
Installation/Operating Instructions
Galaxy
LEC
®
906270 - 315 WATT 120V - 240V
906272 - 315 WATT 277V ONLY
READ THESE INSTRUCTIONS BEFORE FIRING UP YOUR BALLAST
KEEP ORIGINAL PACKAGING— all returns need to be in the original packaging
in order to avoid product damage during shipping. Any damage to products not in
their original packaging will not be covered under warranty.
SAFETY FIRST! Failure to observe the following safety warnings may result in
serious injury. In addition, failure to observe these safety warnings will result in a
waiver of all liabilities and will void all warranties.
WARNING
 If the exterior of the lamp is damaged, replace lamp immediately.
 When re-lamping, make sure lamp has time to cool before touching.
 Make sure lamp is correctly locked into the reflector socket, properly
securing the lamp.
 Make sure power cord and lamp cord are connected properly.
 Disconnect power before re-lamping.
 DO NOT hang by power or lamp cord.
 DO NOT make contact with the interior of the socket while power is on.
 DO NOT operate light systems in wet locations.
 D O NOT plug system into supply voltage other than what is designated on ballast.
 D O NOT attempt to rewire or reconfigure your system, it will void warranty and
could cause serious safety hazards (i.e. power cord, lamp cord, lamp socket or ballast).
 Keep away from children.
®
Electronic Ballast
LIGHT EMITTING CERAMIC
:
®
®

Advertisement

loading

Summary of Contents for Galaxy LEC

  • Page 1 ® Electronic Ballast LIGHT EMITTING CERAMIC ® Installation/Operating Instructions Galaxy ® ® 906270 - 315 WATT 120V - 240V 906272 - 315 WATT 277V ONLY READ THESE INSTRUCTIONS BEFORE FIRING UP YOUR BALLAST KEEP ORIGINAL PACKAGING— all returns need to be in the original packaging in order to avoid product damage during shipping.
  • Page 2  P ower Factor (cosø): > 0.98 (THD): < 15% 3. NOTES  T he Galaxy LEC Electronic Ballast is designed to operate 315 watt ceramic metal halide lamps.  T his unit offers short-circuit and power fluctuation.
  • Page 3 NOTE - Until the lamp has achieved at least 10 hours of operation, the lamp should never be turned off sooner than 2 minutes. This includes installation test. In cases where this happens—you need to wait 1 hour before switching the lamp on again. LAMP REPLACEMENT - Be sure to disconnect the power source before changing lamps.
  • Page 4 TROUBLESHOOTING GUIDE Follow the troubleshooting tips below. If troubleshooting techniques fail, bring ballast back to your place of purchase to request warranty service. POSSIBLE CAUSES CORRECTIVE MAINTENANCE LAMP LOOSE Make sure that the lamp is fully inserted into the socket and that is has been IN SOCKET locked in properly.