Remote controls and annunciators wiring (14 pages)
Summary of Contents for SDC TCC Series
Page 1
TCC/RCC Series Modular Consoles Any su ggestio ns or comme nts to this instruction or prod uct are welco me . P lease con tact us thr ough P:\INST-INS TRUCTIONS\CO NTROL CONSOLES \INST-TCC/RCC REV D 10/20 Page 1 our website o r email eng ineer@sdcsecurity.com...
TABLE OF CONTENTS Product Description Product Features Product Specifications Rocker Switch Types (All outputs are dry outputs) Switch Panel Connector Boards 2.1.1 Rocker Switch Outputs 2.1.2 Reset Button/Key Lock Switch Output 2.1.3 LED/Alarm Power 2.1.4 Control Inputs Direct Connection to Locking Devices with 2-State Status LED (Door Closed) (for AL or BL Series Panels) Direct Connection to Locking Devices with 3-State Status LED...
The consoles can be directly wired to locking devices, or they can be connected via door relay modules such as SDC UR-1 or UR4-8. When used in with a UR-1 or UR4-8, the tri-color LEDs may used to see the status of doors (secure, authorized unlock, forced •...
1.0 INTRODUCTION Product Specifications TCC: TCC: Description: Description: Slope Front Desktop Console Slope Front Desktop Console Color: Color: Black Housing, Beige Top Black Housing, Beige Top 10-1/4”W x 4-3/4”H x 9-5/8"D 10-1/4”W x 4-3/4”H x 9-5/8"D Dimensions: Dimensions: Capacity Capacity 12 stations maximum when using 2 switch panels.
1.0 INTRODUCTION Rocker Switch Types (All outputs are dry outputs Type “A” - Momentary Switches (2-position) Closed Open Open Closed Held Terminal Configuration Normal Activated (Standby) (While Held) Type “B” - Momentary Switches (2-position) Closed Open Closed Open Latched Terminal Configuration Normal Activated...
1.0 INTRODUCTION Switch Panel Configurations Note(s): Panel configurations are only available in 4 or 8 switches. All the switches on a panel are the same type (A, B, C or D). Unless otherwise specified, switches are numbered in sequential order. The first, top-left switch is marked “1”, and then they increase sequentially along the top row.
CONSOLE HARDWARE DESCRIPTION Input/Output Connector Boards All RCC and TCC Consoles are at the factory. All field wiring will be terminated on the (I/O) board . One I/O Board is required for every four switches. The numbers on the I/O boards numbers the switch Reset...
Page 10
2.0 CONSOLE HARDWARE DESCRIPTION Rocker Switch Outputs (x4) Inputs Key lock or Reset Button Switch Power Input Fig 4. Input/Output Board Terminals Buzzer (*L4E or EA pannels only) Fig 5. Input/Output Board Connectors I/O Board Connectors Function J1 – J4 Panel Rocker Switches 1-4, respectively J5 &...
CONSOLE HARDWARE DESCRIPTION Rocker Switch Outputs Each rocker switch output is labeled according to its corresponding rocker switch cap number. The 3-terminal output is marked UP, COM and DN. The electrical configuration of the output is dependent on the panel model type (A, B, C, or D). Refer to Page 5 for all terminal configurations.
3.0 CONSOLE WIRING EXAMPLES Wiring examples are meant to serve as a reference and may not cover the scope of your exact application. Direct Connection to Locking Devices with 2-State Status LED (Door Open / Door Closed) (for AL or BL Series Panels) NOTE: The rocker switch rating must be taken into consideration when connecting locking devices directly through the switch.
CONSOLE WIRING EXAMPLES Direct Connection to Locking Devices with 3-State Status LED (Door Secure / Door Unsecure / Authorized Open) (for AL or BL Series Panels NOTE: The rocker switch rating must be taken into consideration when connecting locking devices directly through the switch. It is recommended to use example 3.3 for locks drawing more than 1 Amp.
3.0 CONSOLE WIRING EXAMPLES Connecting Locking Devices via UR-1 Universal Relay Module (applicable to all panel models) Connecting the console to door locking devices via the UR-1 allows you to isolate lock power, add the capability of timed operation, as well as the ability to report a forced door condition. To operate the door, connect the Normally Open switch to the Trigger A input on the module, then connect the locking device to the access Relay A per the wiring diagram.
Follow the wiring diagram appropriately for fail-safe or fail-secure locks. Be careful to observe lock voltage polarity. NOTE: All low voltage lock wiring shall be 18-gauge minimum (wire gauge shall be determined by the SDC wire gauge chart or another voltage drop too).
Page 16
Check wiring at door for switch continuity and/or voltage. • If connected to doors via external relay modules, check troubleshooting procedures in the appropriate manual. • Contact SDC technical support for further help or application assistance. P:\INST-INS TRUCTIONS\CO NTROL CONSOLES \INST-TCC/RCC REV - 10/20...
Need help?
Do you have a question about the TCC Series and is the answer not in the manual?
Questions and answers