Download Print this page

Troubleshooting - Peco 37610701 - 04 Owner's Manual

Lawn vacuum for a scag unit

Advertisement

TROUBLE SHOOTING
Diagnostic Procedures
Trouble shooting procedures are provided in the chart below. To use these procedures,
first locate the problem description that best describes the trouble that you have encoun-
tered. Check the possible causes one at a time in the list. Correct any problems that are
found and operate the vacuum collector again to verify that you have eliminated the problem.
DO NOT attempt any major repairs without first contacting your dealer.
PROBLEM
Leaves and Grass
not being picked
up completely.
Hoses plug easily.
Vacuum Collector
blower vibrates
excessively.
Unit fails to fill box.
The Serial Number Plate is located
on the aluminum box near the
dump handle.
MODEL 37610701 - 04
CAUSE
1. Engine speed too slow
2. Ground speed too fast.
3. Hose plugged.
1. Grass or leaves too wet.
2. Grass too high.
3. Container full.
4. Grass buildup in boot or
under mower deck.
1. Buildup on blower blades.
2. Bent or chipped blade.
1. Engine speed too slow.
2. Buildup on inlet or screen
3. Grass is too wet or long.
SOLUTION
A. Run at full throttle.
B. Use lower gear
C. Check and tighten all hoses.
D. Unplug hose.
A. Wait for drier conditions.
B. Reduce tractor ground speed/raise deck.
C. Empty container
D. Clean thoroughly.
A. Remove cone and clean blades.
B. Contact your dealer or PeCo.
A. Run at full throttle.
B. Clean thoroughly.
C. Wait for dryer conditions.
OUTDOOR POWER EQUIPMENT
Model Number
Serial Number
Arden, North Carolina 28704
11
PeCo

Advertisement

loading

This manual is also suitable for:

37610701-04