RinKmo EI24 Installation And User Instructions Manual

RinKmo EI24 Installation And User Instructions Manual

Tankless electric water heaters
Hide thumbs Also See for EI24:

Advertisement

TANKLESS ELECTRIC WATER HEATERS
INSTALLATION AND USER INSTRUCTIONS
Before attempting to install the tankless electric water heater, please take the time to read and understand the installation
and safety manual thoroughly and carefully. The manual contains important safety tips and instructions.
Model:
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.
EI24
EI18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EI24 and is the answer not in the manual?

Questions and answers

Summary of Contents for RinKmo EI24

  • Page 1 TANKLESS ELECTRIC WATER HEATERS INSTALLATION AND USER INSTRUCTIONS Model: EI24 EI18 READ AND SAVE THESE INSTRUCTIONS Installer: Leave this manual with the homeowner. Before attempting to install the tankless electric water heater, please take the time to read and understand the installation...
  • Page 2 Failure to comply with the You're covered with Rinkmo 1-year free warranty to instruction may cause property damage, serious injury, or against any manufacturing defect. You are always death;...
  • Page 3: Product Dimensions

    PRODUCT DIMENSIONS MOUNTING YOUR WATER HEATER Accessories contents 13 1/8" (334mm) 3 1/8" 7 1/8" (180mm) Installation location 7 1/8" (180mm) There should be a certain space around the machine for installation and future maintenance. (80mm) Wall or other fixed objects that cannot be moved SUGGESTION: a (side gap): minimum 12"...
  • Page 4: Plumbing Installation

    MOUNTING YOUR WATER HEATER PLUMBING INSTALLATION CAUTION: The plumbing installation must be completed 6. Hang the body on the two Screw before the electrical installation. installed screws, then fix the WARNING: It is the responsibility of the Service Person to other two screws.
  • Page 5: Electrical Installation

    L1 and L2. connector PCB 3 heating EI18 need two circuit breakers. element triac EI24 need three circuit breakers. PCB 3 thermal cut-out triac EI18 EI24 thermal cut-out EI24 PCB 2 heating...
  • Page 6: Troubleshooting

    Display E1 / E0 Inlet temperature Contact: beeps once and all the indicators light up for three sensor failure. rinkmo.service@outlook.com seconds and then go out except power indicator. Power Display E2 / E3 Outlet temperature Contact: indicator is on green, heating indicator and display screen sensor failure.
  • Page 7: Technical Specification

    TECHNICAL SPECIFICATION Model EI18 EI24 Voltage 208V 240V 208V 240V 18.0kW 24.0kW Watts 13.5kW 18.0kW 3x29A 3x34A Amperage draw 2x33A 2x38A @1.5GPM 60℉ 80℉ 80℉ 92℉ Temp @2.25GPM 40℉ 54℉ 53℉ 73℉ Rise @3.0GPM 30℉ 40℉ 40℉ 54℉ Min. wire size...