Greenlee 38568 Specifications And Parts page 7

Hide thumbs Also See for 38568:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Specifications (cont'd)
Hydraulic Power Source
Do not exceed the following hydraulic power source maximums:
Hydraulic flow: 30.3 l/min (8 gpm)
Pressure relief setting: 138 bar (2000 psi)
Back pressure: 13.8 bar (200 psi)
Failure to observe this warning could result in severe injury or death.
Type of Hydraulic System .......................................... Open-center or closed-center
Flow
Minimum .................................................................................18.9 l/min (5 gpm)
Recommended ........................................................................22.7 l/min (6 gpm)
Maximum ................................................................................30.3 l/min (8 gpm)
Filtration ................................................................................... 10 micron (nominal)
Pressure Relief Setting ................................................................ 138 bar (2000 psi)
Back Pressure (maximum)* .......................................................... 13.8 bar (200 psi)
* 13.8 bar (200 psi) is the maximum agreed standard back pressure for the HTMA
(Hydraulic Tool Manufacturers Association). Greenlee Utility tool will operate satis-
factorily at this standard.
1.
Maximum hydraulic fluid temperature must not exceed 60 °C (140 °F).
A sufficient oil cooling capacity is needed to limit the hydraulic fluid temperature.
2.
Hydraulic flow must not exceed 30.3 l/min (8 gpm). Install a flow meter in the
return line to measure the rate of hydraulic flow before using the tool.
3.
Pressure relief valve setting must not exceed 138 bar (2000 psi) at your tool's
maximum flow. Locate the pressure relief valve in the supply circuit to limit
excessive hydraulic pressure to the tool.
Greenlee / A Textron Company
38568 • 43177 • 43178 Long-Reach Chain Saws
7
Hydraulic Schematic
FILTER
(10 MICRON)
RELIEF
VALVE
138 bar
RESERVOIR
(2000 psi)
CONTROL
VALVE
PUMP
POWER SOURCE
Recommended Hydraulic Fluids
Use any non-detergent, petroleum-based hydraulic fluid which meets the following
specifications or HTMA specifications.
S.U.S. @:
38 °C (100 °F) ..................................................................................... 140 to 225
99 °C (210 °F) .................................................................................. 40 minimum
Flash Point .......................................................................170 °C (340 °F) minimum
Pour Point .........................................................................-34 °C (-30 °F) minimum
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
COOLER
T
TOOL
FLOW METER
P

Advertisement

Table of Contents
loading

This manual is also suitable for:

4317743178

Table of Contents