Tyent UCE-E13T User Manual

Under counter extreme

Advertisement

WATER FOR WELLNESS
www.tyentusa.com
The user is responsible for improper use of the
products such as use in any manner for which the
product was not originally intended and any
damage that may occur from such improper use.
This product is subject to changes that enhance
its performance without prior notification.
pH Chart
2.5
4.0
How to Measure pH: Place approximately 2 table-
spoons (30mL) of test water in a container and add 4
drops of pH reagent. Then, mix well and check the
color of the water with the pH chart above (The color
of the water will change according to its pH.)
·
If the power cord is damaged, it must be replaced by
the manufacturer, or a similarly qualified Tyent repair
person in order to avoid a hazard.
This appliance is not intended for use by persons
·
(including children) with reduced physical sensory or
mental capabilities or lack of experience and knowl-
edge, unless they have been given supervision or
instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do
·
not play with the appliance.
MADE IN KOREA
UNDER
COUNTER
EXTREME
11.5
User's Manual
This is Home appliance product.
This product is intended for domestic use only.
Keep this User Manual handy for easy reference.
Carefully read this User Manual, particularly "all safety warnings."
BLACK
LABEL
W A T E R I O N I Z E R

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UCE-E13T and is the answer not in the manual?

Questions and answers

Susan Foster
August 9, 2025

Tyent model UCE-E13T PLUS The lower hose doesn’t have water coming out of it.

User image 689697efb63b1

Summary of Contents for Tyent UCE-E13T

  • Page 1 · If the power cord is damaged, it must be replaced by the manufacturer, or a similarly qualified Tyent repair person in order to avoid a hazard. This appliance is not intended for use by persons ·...
  • Page 2: Table Of Contents

    Under Counter Extreme To Our Valued Customers Table of contents To Our Valued Customers Thank you for purchasing the UCE series Water Ionizer. Table of Contents Please read all safety warnings and this User’s Manual carefully Before Usage before using this product to ensure proper product usage. (Keep Safety Precautions and Warnings themanual handy for easy reference.) Installation Diagram...
  • Page 3: Before Usage

    TDS level without first consulting If you suffer from gastric anacidity, kidney failure or potassium excretion, you ⑤ Tyent USA in orfer to determine if a pre-filter is needed. should not drink functional water.
  • Page 4: Safety Precautions And Warnings

    Under Counter Extreme Safety Precautions and Warnings This appliance is not intended for use by persons (including children) with To reduce the risk of electric shock, do not remove reduced physical, sensory or mental capabilities, or lack of experience and the cover;...
  • Page 5 Under Counter Extreme If the unit is not used for a few days, let the Do not use or store pH reagents near flame. water run for 1-2 minutes before drinking 1-2min (There is a risk of fire) functional water. It is beneficial for the maintenance of the machine to run a strong acidic level for Do not run the water for longer than 1 hour.
  • Page 6: Installation Diagram

    Under Counter Extreme Cleaning Installation Diagram Do not store the unit near chemicals, food, metals or medication benzene Do not spray water on the main unit. Do not clean the unit with chemicals such as benzene or thinner, which may leak into the unit. If using a damp cloth, be very careful not to get the electronic display wet.
  • Page 7: Dispenser Overview

    Under Counter Extreme Dispenser Overview IOnizer Overview Front View Rear View Front View Under Count er Extrem 10:30 16cm 6.3inch 29.5cm 11.6inch 38.2cm 11cm 15inch 4.3inch Nozzle Front cover Door Case ① ④ ⑦ 17.2cm 13.2cm 6.8inch 5.2inch Acidic Outlet Cable Connector Front Case ②...
  • Page 8: Product Features

    See Tyent’s USES guide for more information. Offering both Kitchen Space and Ultimate Beauty 15:00 The TYENT Under Counter Extreme Water Ionizer not only attracts Power SMPS Power Supply System person’s gaze with its well-differentiated appearance, but also helps to upgrade your kitchen’s interior decoration with a neat and luxurious expression.
  • Page 9 Under Counter Extreme Temperature Sensor Function for Safe Operation FRESH, PURIFIED WATER WITH HEALTHY MINERALS IS A MUST! If the temperature of the source water exceeds 95℉ (35℃) then Water Purification Through a Clean Process water will stop flowing and a warning message will appear on the screen.
  • Page 10: Package Contents

    Under Counter Extreme Picture of components can be different from the real ones, and some items may be changed according to advancements in technology. Package Contents Under-Sink Installation Ionizer Dispenser Under Counte r Extrem T-Adapter fixing nut Hose Cool water Rubber Packing O-Rings (2EA) Shut off both the hot and the cold water main supply at the pipe under the sink.
  • Page 11: Dispenser Installation

    Under Counter Extreme Dispenser Installation ⑤ Insert one of the provided rubber O-Rings in the assembled dispenser. First, unscrew the large nut from the ① bottom of the dispenser. ⑥ Place the assembled dispenser into the drilled hole. ② Press the outflow pipes into the holes of Water Outlet Pipe the dispenser.
  • Page 12: Ionizer Installation

    Under Counter Extreme Customer Serviceable Parts Ionizer Installation ATTENTION: If you do not use the TYENT original filter or parts for replacement, it will cause product malfunction, and it will void your warranty. ① Connect the hose from the tap water *If you do not use TYENT original filters, the following problems will occur:...
  • Page 13: How To Change The Filters

    Under Counter Extreme How to Change the Filters How to Reset the Filter Counters ① Shut off the water supply to the unit and unplug the power cord. Open the door in front of the ionizer that’s located underneath your sink. Be sure to keep the ionizer upright while ※...
  • Page 14: How To Use Cleaning Filter

    Leave the machine sit for 3 hours and don’t use. ③ After 3 hours, remove the TYENT Cleaning Filter and install the 2nd filer. ④ Run the unit on the H2O cycle for 5 minutes to wash the inside of the ⑤...
  • Page 15 Under Counter Extreme Menu window LCD Display Push the upper part of LCD Screen. MENU Window appears below the upper part of LCD Screen. Selected mode Set up mode 15:00 Auto flow stop time indicator Voice on/off Cleaning Eco mode on/off Working indicator Push the bottom part of LCD Screen.
  • Page 16: Unit Usage

    Under Counter Extreme Unit usage Message Display When using the TOUCH Screen Press the desired icon on the LCD screen When the screen above appears (or This display means that the water outflow pops up), the filter needs to be replaced. has been stopped prior because of the suspension of water supplied to the unit.
  • Page 17: Ph Level Adjustment

    Under Counter Extreme When using the JOG DIAL pH Level Adjustment Turn the jog dial in either direction H Level Adjustment to select the desired function. The white highlight signals which function is selected. pH Chart 11.5 When the screen changes to the selected color, push the center of 15:00 the dial to start the water outflow.
  • Page 18: System Setup Method

    Under Counter Extreme SYSTEM SETUP METHOD Acidic H Level Adjustment ALKALI pH Level Adjustment Press the top left corner of the screen. MENU options will fall below upper part of screen. Press the top left corner of the screen. MENU Press the setup icon.
  • Page 19 Under Counter Extreme LANGUAGE MODE Volume Level Adjustment Press the top left corner of the screen. MENU Press the top left corner of screen. MENU options options will fall below upper part of screen. will fall below upper part of the screen. Press the setup icon.
  • Page 20 Under Counter Extreme Setting the TIME TOUCH Press the top left corner of screen. MENU options Press the top left corner of screen. MENU options will fall below upper part of the screen. will fall below upper part of the screen. Press the setup icon.
  • Page 21: Selecting Voice On/Off

    Under Counter Extreme User may manually clean the unit whenever desired. Selecting Voice On/Off Cleaning Function Cleaning can take place automatically and/or manually. Press the top left corner of screen. MENU The automatic cleaning cycle will run after more than 12 hours of options will fall below upper part of screen.
  • Page 22: Eco Mode

    Under Counter Extreme ECO Mode is a feature for saving power consumption during periods of non-use. ECO MODE TURBO Function The TURBO function allows you to create strong alkaline and strong acidic water. These types of waters are ONLY to be used for cleaning, sanitizing, Press the top left corner of screen.
  • Page 23: Usage Recommendations

    Under Counter Extreme Usage Recommendations 15:00 15:00 15:00 15:00 Light Acidic Water Medium Acidic Water (DO NOT DRINK) (DO NOT DRINK) Approx 5.5 pH Approx 4.5 pH For washing hands and face. For washing vegetables and fruits. Light Alkaline Water Medium Alkaline Water ※DO NOT DRINK.
  • Page 24: Temperature Sensor

    Product Name Water Ionizer ℉ (35℃) get into the unit, the water supply will automatically be shut off and the unit will stop operating. Model Number UCE-E13T Purifying Mode TM Filtration Mode In flow Rated Power AC100V~AC130V, AC200~AC240V/50Hz~60Hz LCD:“TEMP ERROR”...
  • Page 25: Troubleshooting

    3. Check if the flow rates are low (less than 1ℓ/ min.). Contact Tyent for replacements filters. You’ll need to install a water pump. Please consult with a Tyent technician. Check if your water supply is cut off or if the water supply line is frozen.
  • Page 26 This warranty is non-transferable and valid only for the original owner. Product Name Water Ionizer Warranty Period Lifetime Tyent Water Ionizer UCE-13 □ (above conditions apply) Customer’s Name/Phone Date of Purchase Customer’s Address Installation Date/Name...

Table of Contents