VIKTIGT: Läs denna manual innan produkten monteras, ansluts och tas i bruk.
Spara manualen för framtida bruk .................................................................................................................. 2
FI
Käyttöopas AW DX sisäyksikölle lämpöpumpulle.
TÄRKEÄÄ: Lue tämä opas ennen laitteen asennusta, liitäntää ja käyttöönottoa.
Säilytä opas myöhempää käyttöä varten. ......................................................................................................8
GB
Manual AW DX for the indoor unit.
IMPORTANT: Please read this manual before installation, connection and putting the product into use.
Save the manual for future use. .....................................................................................................................14
DE
Handbuch AW DX für Inneneinheit.
WICHTIG: Lesen Sie die Betriebsanleitung, bevor Sie das Gerät montieren, anschliessen und in
Betrieb nehmen.
Bewahren Sie die Betriebsanleitung für den zukünftigen Betrieb auf.......................................................20
Page 1
AW DX Manual AW DX för inomhusdel till värmepump. VIKTIGT: Läs denna manual innan produkten monteras, ansluts och tas i bruk. Spara manualen för framtida bruk ........................2 Käyttöopas AW DX sisäyksikölle lämpöpumpulle. TÄRKEÄÄ: Lue tämä opas ennen laitteen asennusta, liitäntää ja käyttöönottoa.
Page 2
Dimensioning of external element and heat pump convector/internal element When combining the outdoor unit with the indoor unit AW DX, it is important that the internal volume of the AW DX coil meets the recommendations of the outdoor unit manufacturer for best and safe operation.
AW DX INSTALLING THE WALL BRACKET 1. Loosen the eight screws; see arrow markings in Fig 1. Fig. 1 Fig. 2 2. Install the wall brackets with the hole facing the fan; see marking in Fig 2. This hole is for a cable tie for the cable of the fan motor.
Page 4
AW DX 3. Pull off the rubber seal from the connection pipe and protect the sheet against discolouration with a flame retardant, see Fig. 7. Attention! Make sure the nitrogen can freely exit so that no overpressure occurs during soldering.
Page 5
Fig. 16 ACCESSORY An air deflector is available as an accessory for the AW DX, which directs the air to the sides, see Fig. 16. It is screwed into the of the top and bottom plates with self drilling screws.
AW DX MAINTENANCE/CLEANING Before starting maintenance/cleaning, the indoor unit must be de-energised. Maintenance/cleaning must be carried out by a maintenance company or a qualified person. Attention! The air distribution plate on the indoor unit must always be installed, otherwise the heat capacity drops significantly.
Page 7
AW DX 4. Hold the air distribution plate at an angle and take it out, see Fig. 20. Make sure that the coil element is not damaged! Fig. 20 Fig. 21 5. Clean the fan grille, fan motor, fan motor air vents, and coil with a soft brush and a vacuum cleaner.
AW DX Appendix A Technical data Type AW DX22 AW DX42 Power supply 230 V 230 V Current max. 0.95 Air volume m³/h 2000 3500 Sound pressure level dB(A) Max. operating pressure 4.15 4.15 Inner volume coil liter Pipe connection coil, liquid/gas Ø...
AW DX Anhang A Technische Daten AW DX22 AW DX42 Spannung 230 V~ 230 V~ Stromverbrauch 0,95 Luftmenge m³/h 2000 3500 Schalldruckpegel dB(A) Max. Betriebsdruck 4,15 4,15 Innenvolumen Coilelement Liter Rohranschluss Kühlrohr, Flüssigkeit/Gas Ø 3/8” - 5/8” 3/8” - 5/8”...
Page 11
AW DX NB: We reserve us from typographical errors and the right to make changes and improvements to the contents of this manual without prior notice. VEAB Heat Tech AB Visitors adress Org.no/F-skatt Postal Cheque Service Phone Box 265 Stattenavägen 50...
Need help?
Do you have a question about the AW DX and is the answer not in the manual?