Advertisement

USER MANUAL
ATH AC134a
© Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014
1 / 36

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AC134a and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ATH-Heinl AC134a

  • Page 1 USER MANUAL ATH AC134a © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 1 / 36...
  • Page 2: Table Of Contents

    Weight input for empty tanks ............................ 28 Service interval ................................29 Troubleshooting ................................30 Warranty ..................................33 Notes .................................... 34 © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 2 / 36...
  • Page 3: General Information

    ATH-Heinl GmbH & Co.KG reserves all rights to make changes at any time without notice. © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 3 / 36...
  • Page 4: Disposal Of The Device

    Authorized: Mrs. Anja Antikidis-Heinl, Mrs. Corinna Heinl Brand: ATH-Heinl Category: 6 Device: Electrical and electronic tools for use in non-private households © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 4 / 36...
  • Page 5: Safety Instructions

    © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 5 / 36...
  • Page 6 The AC134a eco may not be used for air-conditioning that have the R12 as refrigerant. © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 6 / 36...
  • Page 7: Introduction

    The AC134 eco is equipped with special connectors to avoid the risk of contamination with other units which are using R12 as refrigerant. © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 7 / 36...
  • Page 8: Specifications

    TFT color display 105.5*67.2mm, 480 x 272 Pixel Length of the service tubes 3.000 mm © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 8 / 36...
  • Page 9: Function Table

    Direct control of the internal electronic components, solenoid valves, compressor, vacuum pump. This is used to check if a fault occurs. © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 9 / 36...
  • Page 10: Parts Description

    Parts description © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 10 / 36...
  • Page 11 Gas cylinder support panel KKT4000 Refrigerant gas cylinder KDR6000 Printer KDM4000, KDM4001, Pressure gauges KDM4000 © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 11 / 36...
  • Page 12: Panel Survey

    Keypad EXIT, Cancel/back ENTER, Confirm/next Selection keys, high, down, to the left, to the right © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 12 / 36...
  • Page 13: Commissioning

    Commissioning  Removing the transportation safety (removing the protective material and fuses of the scales) © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 13 / 36...
  • Page 14: Filling Of Refrigerant, Pag Oil And Uv

    Then remove the external refrigerant bottle. The A/C device is now ready for use. © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 14 / 36...
  • Page 15: A/C Wiring Diagram

    While vacuuming and while all other work on the A/C vehicle system, turn off the A/C system and the engine. It is essential to note the specifications of the vehicle manufacturer. © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 15 / 36...
  • Page 16: Suction (Recovery)

    Suction (Recovery) © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 16 / 36...
  • Page 17: Vacuum

    Vacuum © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 17 / 36...
  • Page 18: Adding Oil

    Adding oil © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 18 / 36...
  • Page 19: Filling

    If YES is selected, please follow the instructions on the screen. (See next page) © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 19 / 36...
  • Page 20 After flushing the device can be switched off and connected to the vehicle to check the pressure from the vehicle system via the HP, LP pressure gauge. © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 20 / 36...
  • Page 21: Automatic Procedure

    The function "tube flushing" can be performed in automatic mode, while the actual amount of refrigerant to the system can be seen. © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 21 / 36...
  • Page 22 4. System flushing of the device 5. Unit of measurement 6. Weight input for empty tanks Password 111111 Language © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 22 / 36...
  • Page 23: Calibration

    1. Remove back cover 2. Remove refrigerant cylinder and make sure that nothing is on the scale. © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 23 / 36...
  • Page 24 1. Place an object with 11-15 kg on the scale. Then enter the calibration weight. 2. Confirm with ENTER © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 24 / 36...
  • Page 25: Scale For Uv, New And Used Oil Tank

    Attach the calibration weight as shown in the image. 3. Confirm with ENTER Step 3 © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 25 / 36...
  • Page 26 Place an object with 3-4 kg on the scale. Then enter the calibration weight. Attach the calibration weight as shown in the image. © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 26 / 36...
  • Page 27: Pressure Relief

    This function is used to release the refrigerant tank manually if a failure of the automatic control is present. © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 27 / 36...
  • Page 28: Unit Of Measurement

    For security reasons this function is only available for the service technician and not for the user. © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 28 / 36...
  • Page 29: Service Interval

    Now you can´t run any operation until the interval is reset from the merchant. © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 29 / 36...
  • Page 30: Troubleshooting

    Pressure sensor doesn´t work Check the connection of the pressure sensor to the board or replace pressure sensor © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 30 / 36...
  • Page 31 First perform recovery function Magnet valve for the filling does not Check magnet valve Nr.- 5. work © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 31 / 36...
  • Page 32 Check the valve block for contamination, if necessary replace seal and clean the valve block. © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 32 / 36...
  • Page 33: Warranty

    If this should be done under warranty, the repair is free for you. If the warranty period is over, you have © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014...
  • Page 34: Notes

    Notes © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 34 / 36...
  • Page 35 ______________________________________________________________________________________________________ © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 35 / 36...
  • Page 36 © Copyright by ATH-Heinl GmbH & Co. KG, 2014, All rights reserved. / Subject to misprints and technical changes / Version: 05/2014 36 / 36...

Table of Contents