Domestic CRX50 Installation And Operating Manual page 28

Compressor refrigerator
Table of Contents

Advertisement

Installing and connecting the refrigerator
CRX50DC, CRX65DC, CRX80DC, CRX110DC
You can connect the refrigerator to 100 – 240 Vw AC power if you use the MPS35
rectifier (accessory).
The MPS35 rectifier features a priority circuit which conserves the battery con-
nected. When a 100 – 240 Vw mains connection is used, the rectifier automatically
switches from battery to mains operation.
When disconnected from the 100 – 240 Vw mains supply, the rectifier automatically
switches back to battery operation. Mains operation via the rectifier always takes pri-
ority over battery operation.
In mains operation the output voltage of the rectifier will always be 24 V. When the
rectifier is in 12 V or 24 V battery operation, the input voltage will be passed through
so that the output voltage equals the input voltage.
Proceed as follows when you connect the refrigerator to the AC supply:
1. Attach the rectifier on the back of the refrigerator.
h
2
100 – 240 V~
bk
rd/bk
10 A
12 V/24 V
2. Connect the rectifier as shown in fig. h.
3. Connect the refrigerator to the rectifier (fig. h 1):
– Red cable (rd): positive battery terminal
– Black cable (bk): negative battery terminal
4. Plug the connector (fig. h 2) into the AC socket.
28
+
CRX
+
rd
bk
1
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Crx65Crx80Crx110Crx140

Table of Contents