SAFETY INSTRUCTIONS CAUTION - This product should be installed by a professional service technician or similar person who is qualified in electrical equipment installation. Improper installation and/or operation could cause serious personal injury, property damage or death. Improper installation and/or operation will void the warranty. CAUTION - The device must be connected only to a supply circuit that is protected by a Ground Fault Circuit Interrupter (GFCI).
Page 3
DESCRIPTION Renaissance combines an Ultraviolet Sterilization Chamber with Ozone (O3) disinfection to treat your water. These two powerful processes eliminate 99.99% of all contaminants in water and reduce the use of pool chemicals up to 80%. No toxic chemicals are used, no metals or minerals, only pure light and pure oxygen.
System On (Flashing - No Flow) Optimum Water Conditions pH: 7.2 - 7.6 Total Alkalinity: 80-120 ppm Check Manual Stabilizer: 50-80 ppm or Our Website Calcium Hardness: 200-400 www.solaxx.com Water Water from 10 Ft. Low return pool Voltage Cable to pool...
Page 5
INSTALLATION 2. INSERT BULB INTO CHAMBER: IMPORTANT: HANDLE THE BULB BY THE ENDS ONLY AND AVOID TOUCHING THE CLEAR GLASS OF THE BULB. IF POSSIBLE USE COTTON GLOVES TO HANDLE BULB TO AVOID GETTING OILS FOM HANDS ON THE BULB. SKIN OILS ATTACH TO THE BULB AND SHORTEN ITS EFFECTIVE LIFE. IF BULB IS TOUCHED, WIPE CLEAN WITH A SOFT CLOTH AND RUBBING ALCOHOL.
Page 6
7.2 - 7.6 Total Alkalinity: 80-120 ppm Total Alkalinity: 80-120 ppm Check Manual Stabilizer: 50-80 ppm Check Manual Stabilizer: 50-80 ppm Calcium Hardness: 200-400 Calcium Hardness: 200-400 or Our Website or Our Website Line Line www.solaxx.com www.solaxx.com Ground Ground Pump Pump...
Stabilizer: 50-80 ppm Stabilizer: 50-80 ppm Calcium Hardness: 200-400 or Our Website Calcium Hardness: 200-400 www.solaxx.com OPERATION When power is supplied to the system, the perimeter of the power supply mirrors the LED lights in the center of the faceplate overlay in...
MAINTENANCE WINTERIZING A. Unthread end cap from chamber with wire connection. Unplug bulb and GENTLY push bulb back into chamber B. Unthread tube connection to manifold (hold tube and turn nut) C. Unthread union nuts and pull chamber from top of manifold. The union nuts should be loosened by hand.
Page 9
MAINTENANCE BULB REPLACEMENT The UV bulb is rated for 13,000 hours of service and can be monitored through the blue viewing ports at either end of the chamber. When the bulb requires replacement, follow this simple procedure: Shut off AC power to Renaissance before performing maintenance Allow bulb to cool for 10 minutes before handling A.
The consumer is responsible for establishing the original purchase date and the purchaser's identity for warranty purposes. The consumer is responsible for filling out the Warranty form and to send it to the manufacturer or completing the warranty registration form on www.solaxx.com.
Page 12
R E N A I S S A N C E Pure Water From UV and Ozone www.solaxx.com...