Seneca T201DC100 Installation And User Manual

Passive transducer of direct current 100 adc, for 4 – 20 ma current loop

Advertisement

Quick Links

INSTALLATION AND USER'S GUIDE
Language manual
Product
Description
Series of product
Contents:
3.5 Connector
3.7 Reference standards
4.0 Preliminary use instructions
5.2 Current input.
5.3 Connection to the DIN rail
SENECA s.r.l.
Manufacturer
Via Austria, 26 - 35127 - PADOVA - ITALY
Tel.+39.049.8705355 - 8705359 - Fax +39.049.8706287
Web
Manuals and configuration software are available at www.seneca.it
supporto@seneca.it
Mail
commerciale@seneca.it
This document is property of SENECA srl. Duplication and reprodution are forbidden, if not authorized. Contents of
the present documentation refers to products and technologies described in it. All technical data contained in the
document may be modified without prior notice Content of this documentation is subject to periodical revision.
Passive transducer of direct current
100 Adc, for 4 - 20 mA current loop
Pag.
2
2
2
4
4
6
MI00353-2-EN
English
T201DC100
T
ENGLISH 1/5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T201DC100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Seneca T201DC100

  • Page 1 Mail commerciale@seneca.it This document is property of SENECA srl. Duplication and reprodution are forbidden, if not authorized. Contents of the present documentation refers to products and technologies described in it. All technical data contained in the document may be modified without prior notice Content of this documentation is subject to periodical revision.
  • Page 2 2.1 Description The T201DC100 is an isolated and passive, contact-less loop powered direct current transducer. The T201DC100 has functions and look very similar to a standard current transformer, but it is enabled to measuring the continuous current component that flowing through it.
  • Page 3 - Unipolar 0 – 10 A, Bipolar -10 – 0 – +10 A - Unipolar 0 – 25 A, Bipolar -25 – 0 – +25 A Range - Unipolar 0 – 50 A, Bipolar -10 – 0 – +50 A - Unipolar 0 –...
  • Page 4 97 mm 4.0 PRELIMINARY INSTRUCTION FOR USE The T201DC100 can be installed in any position and place in accordance to expected environmental conditions. Use the included holder bracket when fixing to a DIN rail. High-strength static magnetic fields may change the output value: keep away from permanent magnets, electromagnets or iron bulks that cause such a modification of the surrounding magnetic field;...
  • Page 5 5.2 Connection for reading input current To measure the current flowing through the cable, plug the cable into the center hole of T201DC100 (as shown in the figure). The maximum current that can be measured using T201DC100 is 100A. To increase the sensitivity of current measurement, insert the wire several times through the center hole T201DC100, creating a series of turns.