1.
INSTRUMENT FUNCTION..............................................................................................2
2.
KEYS AND DISPLAY.......................................................................................................3
2.1
The keys function............................................................................................................3
2.2
The parameters display................................................................................................... 4
2.3
The connection................................................................................................................ 5
3.
INSTALLATION................................................................................................................5
3.1
The basic equipment components...................................................................................5
3.2
The instrument installation............................................................................................. 6
3.2.1
3.2.2
3.2.3
4.
OPERATION...................................................................................................................... 6
5.
THE USAGE OF KEYS..................................................................................................... 7
5.1
The start and stop key..................................................................................................... 7
5.2
The value key ↓............................................................................................................ 7
5.3
The value key ↑............................................................................................................ 7
5.4
The brightness key ↓.................................................................................................... 7
5.5
The brightness key ↑.................................................................................................... 7
5.6
The signal key ↓........................................................................................................... 8
5.7
The signal key ↑........................................................................................................... 8
5.8
The beat number key.......................................................................................................8
5.9
The display mode key..................................................................................................... 8
5.10
The lift angle key............................................................................................................ 8
5.11
The printer key................................................................................................................ 8
5.12
The period key.................................................................................................................9
5.13
The speaker key...............................................................................................................9
6.
THE PARAMETERS......................................................................................................... 9
6.1
6.2
The lift angle................................................................................................................. 10
6.3
The test period...............................................................................................................10
7.
THE TECHNICAL DATA............................................................................................... 10
8.
THE INSTRUMENT MATAINCE..................................................................................11
8.1
There is no reaction for the instrument after power on................................................ 11
8.2
installing the sensor...................................................................................................................11
8.3

Table of Contents

....................................................................................6
...................................................................................... 6
............................................................................................. 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Weishi 2000

  • Page 1: Table Of Contents

    The WeiShi No.2000 User Manual Table of Contents INSTRUMENT FUNCTION....................2 KEYS AND DISPLAY.......................3 The keys function......................3 The parameters display....................4 The connection........................ 5 INSTALLATION........................5 The basic equipment components...................5 The instrument installation..................... 6 ..................6 3.2.1 The power supply installation ..................6 3.2.2...
  • Page 2: Instrument Function

    INSTRUMENT FUNCTION The WeiShi No.2000 is a precise mechanical watches test instrument. It is used for multi-testing mechanical watch by watch manufacturers and watch technician, which is the below feature: 1. The LED screen can completely display the watch frequency.
  • Page 3: Keys And Display

    KEYS AND DISPLAY The keys function No.2000 SIGNAL BEAT NUMBER LIFT ANGLE MODE PRINT PERIOD SPEAKER MULTIFUNCTION TIMEGRAPHER START / STOP VALUE Start/Stop The key used for start/stop to test the watch Value↓ The key used for selection of the next lower value Value↑...
  • Page 4: The Parameters Display

    Lift Angle The key used for adjustment the lift angle Print The key used for the out-print. Period The key used for the test period Speaker The key used for power on/off the speaker The parameters display RATE:0s/d AMP.:0° B.E.:0.0ms BEATRATE: PERIOD: LIFTANGLE:...
  • Page 5: The Connection

    The connection The microphone connector The frequency calibration connector (Just for the engineer use) The printer connector The power supply connector (Adaptation range for 10 – 15V DC) INSTALLATION The basic equipment components A The test hosts B The microphone C The power cable...
  • Page 6: The Instrument Installation

    D The user manual The instrument installation ATTENTION: The instrument is to be installed in such a way: it is not directly exposed under the sunlight or up to 60℃. The microphone should be placed at the sufficient distance from noisy machines, loudspeakers, sharp stroke sound and particularly from ultrasonic cleaning machines.
  • Page 7: The Usage Of Keys

    remove from the sensor after confirmation test orientation. The Green LED is flashing, meaning that it has received the watch signal. THE USAGE OF KEYS The start and stop key You need to pauses the instrument by usage the start/stop key when setting the parameter (The brightness and signal key can adjust at any time.) After setting the parameters and press the start/stop key again, the instrument can start the test state once again.
  • Page 8: The Signal Key

    The brightness key can adjust the brightness freely in the test process, but ↓ the instrument doesn’t store the settings. The signal key ↓ The key can decrease the input signal. The signal key ↑ The key can increase the input signal. The beat number key At first press the start/stop key (The LED is in red), and then press the beat number key, you can manually adjust the bear number when the beat number...
  • Page 9: The Period Key

    press the start/stop key to pause the machine (The LED is in red), the printer will print the data after pressing the printer key again. Press the start/stop key one time if need to continue the test or stop the print. 5.12 The period key First press the start/stop key (The LED is in red), and then press the period key, you can manually adjust the period by pressing the value key ↑↓...
  • Page 10: The Lift Angle

    The lift angle Most of the movement lift angle is 52°, so the instrument setting lift angle is 52°. The lift angle degree can set between 30° and 70° when calculating the amplitude. The test period The test period is: 2S, 4S, 8S, 12S, 20S, 30S, 60S; the base time for calculate the average test result.
  • Page 11: The Instrument Mataince

    ·The supply voltage: The single 100 - 240V~, 50 – 60Hz. ·The measurement orientation: Six kinds of orientation. ·The use of the environment: 0 - 50℃, the relative humidity is 0 - 80﹪RH. ·The instrument outer case: The light grey in plastic cement. ·The dimensions: 29*20*19 cm.