Summary of Contents for Parametric PCR2-EU868-IN

  • Page 1 QUICKSTART GUIDE LoRaWAN™ Radar Peopleflow Sensor bi-directional PCR2-EU868-IN PCR2-US915-IN PCR2-AU915-IN PCR2-AS923-IN LoRaWAN Certified is a mark used under license from the LoRa Alliance™. www.parametric.ch/product/pcr2...
  • Page 2: Preparing The Device

    PREPARING THE DEVICE 1 Opening the Enclosure Remove the four screws from the casing to gain access to the device. 2 Connecting the Programming Cable Connect the sensor to your Computer using a USB Cable. www.parametric.ch/products/pcr2-in...
  • Page 3 3 Install PCR Setup Tool Download the free PCR Setup Tool by opening the following URL: https://www.parametric.ch/kb/pcr-setup-tool Follow the instructions of the installer. Ignore all security warnings. Note: This is a .Net Application. You may need to install additional software from Microsoft.
  • Page 4 Count poeple and send if counter values are >0 Trigger : Movement detection mode 7 Change Uplink Interval 8 Over-the-air configuration Most of the settings can be changed by sending a LoRaWAN downlink to port 190. Find more information on this in our Knowledge Base: https://parametric.ch/kb www.parametric.ch/products/pcr2-in...
  • Page 5: Installing The Device

    Installation height: Installation direction: Device surface parallel to peopleflow 6…10m depending on object size Detection range: Separation angle: 40° (Distance between persons) Avoid: Side-by-side walking Groups Too close to each other See also Limits of PCR2 in our Knowledgebase: https://www.parametric.ch/kb/pcr2-limits/ www.parametric.ch/products/pcr2-in...
  • Page 6 Heading down, LEDs in line with direction of movement Separation angle: 40° (Distance between persons) Avoid: Side-by-side walking Groups Too close to each other Too wide entries (detection angle is 34°) See also Limits of PCR2 in our Knowledgebase: https://www.parametric.ch/kb/pcr2-limits/ www.parametric.ch/products/pcr2-in...
  • Page 7 Use a 5…12V DC power supply and connect to the micro push-in terminals. Use 22AWG ... 18AWG (0.2 – 0.75mm ) stranded wires carefully push the lever with a screwdriver or ballpen ferrules are not required with these terminals check polarization www.parametric.ch/products/pcr2-in...
  • Page 8: Operation

    In the interest of continuous further development of our equipment, we make changes to the scope of delivery in form, technology and equipment reserved. We also ask for your understanding that no claim can be derived from data and illustrations of this manual. Parametric GmbH Waldeggstrasse 82 3800 Interlaken Switzerland www.parametric.ch...

This manual is also suitable for:

Pcr2-us915-inPcr2-au915-inPcr2-as923-in