2 Electrical Installation
The device can by powered by using the USB socket or the DC terminals. Open the
enclosure end connect your cable. The cable can be routed through the cable membrane on
the backside of the enclosure.
USB powered
Use USB Power Supply with Micro-USB-B plug connected to CONFIG socket.
DC powered
Use a 5...12V DC power supply and connect to the micro push-in terminals.
+
-
Use 22AWG ... 18AWG (0.2 – 0.75mm
-
-
carefully push the lever with a screwdriver or ballpen
-
ferrules are not required with these terminals
-
check polarization
) stranded wires