AIR FILTER INSTALLATION
Oven ships with two (2) Air Filters taped to the floor of the oven interior.
Do NOT operate oven without the air filters installed.
1.
Remove and discard tape.
2.
Locate air filter in the recessed grills along the base of the left and right sides of the oven.
3.
Angle the Air Filter with the lower edge placed inside the bottom of the recessed grill.
4.
Rotate the top of the air filter to snap into place.
5.
Repeat steps 2-4 for the other side and air filter.
A
B
C
D
OVEN CLEARANCES
A.
Allow at least 2" (5.1 cm) of clearance
around top of oven. Proper air flow around
oven cools electrical components. With
restricted air flow, oven may not operate
properly and life of electrical parts is
reduced.
B.
There is not an installation clearance
requirement for the back of the oven.
C.
Allow at least 1" (2.54 cm) of clearance
around sides of oven.
D.
Install oven so oven bottom is at least
3 feet (91.5 cm) above floor.
So...how do I use it?
Manual Time Entry Mode
Time entry mode allows the user to manually enter cook time and power level, without
changing the preset program keypads.
1.
Open oven door, place food in oven, and close door.
2.
Press and hold number keypad "1"/ TIME ENTRY.
3.
Press number keypads to enter desired cook time.
4.
Press and hold number keypad "2"/ POWER LEVEL to change power level.
• Press number keypads to enter % microwave power ("1"=10%, "2"=20%,etc.)
For 100% power level, press and hold number keypad "2"/ POWER LEVEL.
5.
Press START/OK keypad to begin cooking.
6.
At the end of the cooking cycle, the oven beeps. Carefully remove food from oven.
Programming Mode
1.
Press and hold number keypad "3"/ PROGRAM.
2.
Press number keypad(s) to open the desired program location.
3.
To edit name: Press number keypad "0". Press number keypads to enter recipe name.
Press START/OK keypad.
4.
To edit cook time for Stage One: Press number keypad "1". Press number keypads to
enter cook time. Press START/OK keypad.
To edit power level for Stage One: Press number keypad "5". Press number keypads to
5.
enter % microwave power ("1"=10%, "2"=20%,etc.). For 100% power level, press and hold
number keypad "2"/ POWER LEVEL.
6.
If stage cooking is desired, repeat steps 4-5 for each additional stage, substituting
corresponding number keypads for each stage.
7.
To save and exit programming mode: Press START/OK keypad.
©2020 ACP, Inc.
Cedar Rapids, IA 52404
Quick Start Guide
Refer to Owner's Manual for Safety Statements. Complete Owner's Manual available online.
This document covers HDC*-Y* and MDC*-Y* models
A
(A)
B
C
D
CONTROL PANEL FEATURES
(A) USB Port
(B) Display
(C) Number Keypads
(D) Start/ OK Keypad
(E) Stop/ Reset Keypad
Air Filters
3
(B)
(F)
(i)
(ii)
(iii) (iv)
(F) Secondary Function Keypads
To activate, press and hold corresponding
number keypad.
(i)
(ii)
(iii)
(iv) User Options (number keypad "4")
(v)
(vi) Menu A/B (keypad "6")
Preset Program Keypads
To cook food using preprogrammed cooking
sequences:
1.
2.
3.
4.
X2 - DOUBLE QUANTITY COOKING
1.
2.
MENU A/B (select models)
Press and hold number keypad "6" to toggle
between A and B menus.
2
4
(C)
(D) (E)
(v) (vi)
Manual Time Entry Mode (keypad "1")
Power Level (keypad "2")
Programming Mode (keypad "3")
X2 - Double Quantity Cooking (keypad "5")
Open oven door, place food in oven, and
close oven door.
Press desired number keypad(s).
Oven operates and time counts down.
At the end of the cooking cycle, the oven
beeps. Carefully remove food from oven.
Press and hold number keypad "5"/ X2 to
toggle double quantity feature ON.
"X2" appears at top center of screen
when enabled.
Press desired number keypad(s).
Display counts down cooking time for
two quantities.
Part No. 20289100
Original Instructions

Advertisement

loading

Summary of Contents for ACP HDC Y Series

  • Page 1 If stage cooking is desired, repeat steps 4-5 for each additional stage, substituting corresponding number keypads for each stage. To save and exit programming mode: Press START/OK keypad. ©2020 ACP, Inc. Part No. 20289100 Cedar Rapids, IA 52404 Original Instructions...
  • Page 2 0.31 Ohms at the interface point of the user’s supply. The user has to ensure that this device is connected only to a power supply system which fulfills the requirement above. If necessary, the user can ask the public power supply company for the system impedance at the interface point. ©2020 ACP, Inc. For full product documentation visit: Part No.

This manual is also suitable for:

Mdc y seriesMdc10y15Mdc12ya2Mdc18y2Mdc21y2