Product description
The MB-PULSE4 module is a device that allows to convert the incoming pulses into a
Wired MBUS signal. It is equipped with four inputs, so it is possible to simultaneously
connect up to four pulse emitter devices. The device must be configured by using the
BMBUS configuration software. This allows to set primary address, medium options,
measurement units, pulse value and it allows to read and manage the MBUS network,
when properly connected to a compatible level converter. To download the software,
please connect to the following link
http://www.bmeters.com/en/bm_product/m-bus-
master/
and press the button "software". Please refer to the configuration software
manual for a detailed description of the configuration features and options available.
The module can be connected to any meter equipped with pulse output, regardless the
brand, size and version.
Package Content
MB-PULSE4 module
Anti-tampering seal
Installation guide
Technical data
Working temperature: From +1°C to +55 °C
Power supply voltage: MBUS network + Lithium battery 3V Li-SOCI
Maximum battery duration: 1 year**
MBUS consumption: 1 unit load (≤1,5 mA)
Transmission protocol: MBUS EN14757-3
Configuration: by using BMBUS software***
Protection level: IP65
Measurement units available: L- Wh – Kj – N/A
Mediums available: Electricity, water, hot/cold water, heat cost allocator (HCA),
heat meter, cooling meter, gas, oil, pressure, other
Dimensions: 70mm x 139mm H=35mm
Weight: 100g
* Battery is replaceable, spare batteries are supplied by B METERS, DO NOT REPLEACE the battery with
wrong types. Disconnecting the battery from the board and the module from the network in the same
time will cause the configuration lost, it will be necessary to reconfigure the device.
** In the event that the module remains permanently disconnected from the MBUS network
*** even during the configuration it is necessary that the device stays connected to a MBUS network
and to a MBUS master
Installation
The module should be mounted on the wall, by using two screws on the two holes
pointed out by the arrows in the picture below.
To open the device, remove the four screws on the edges of the cover and lift it
carefully.
MB-PULSE4_QUG v1.0
(backup)*
Connections
2
Plug the cables of pulse output devices and MBUS network passing through the rubber
cable-glands available, marked as Input 1-2 and Input 3-4 in the picture above.
Input 1-2: Connect the wires of the first pulse output to the A and B terminals, as shown
in the picture. Connect the wires of the second pulse output to the C and D terminals,
as shown in the picture.
Input 3-4: Connect the wires of the third pulse output to the E and F terminals, as shown
in the picture. Connect the wires of the fourth pulse output to the G and H terminals,
as shown in the picture.
MBUS: connect the device to the MBUS network by using the X and Y terminals.
Contacts type
Counting contacts: A [+] / B [-] for meter n.1, C [+] / D [-] for meter n.2, E [+] / F [-] for
meter n.3, G [+] / H [-] for meter n.4.
It is possible to connect pulse output devices both REED and Open Collector type. In
this second case, it is necessary to respect the polarity.
Configuration
Configure the module by using the BMBUS software.
The device will then answer via MBUS with four different secondary addresses, one per
each input. The default addresses are the following:
 Input 1: Serial Number + 01 (e.g.: 12345601);
 Input 2: Serial Number + 02 (e.g.: 12345602);
 Input 3: Serial Number + 03 (e.g.: 12345603);
 Input 4: Serial Number + 04 (e.g.: 12345604);
When the configuration is completed, close the box with the screws.
To avoid any potential tampering of the module, you can place the anti-tampering seal
(supplied together with the module) between the base of the box and the cover.
Safety
 During the installation process, handle the device with care, don't crush, don't bent,
don't exposure to electrostatic discharges which could damage permanently the
device, do not install close to heat sources (radiators, conditioners, convectors etc..).
Quick User Guide
The MB-PULSE4 module doesn't contain hazardous materials in accordance with
European directives 91/157/EEC, 93/86/EEC, and 2002/95/EC(RoHS). The device
requires specific disposal on the end of its lifetime. Recycling is mandatory or
recommended following the Directive RAEE 2012/19/UE inside European Union
region, or anyway dispose in accordance with local laws and regulations. Do not
burn, or undergo to high temperatures.
The MB-PULSE4 works reliably in the environmental conditions specified in this
manual. Any unauthorized intervention and/or modification may cause
malfunctions or total damaging of the product.
Warranty
The warranty period is set at 24 (twenty-four) months from the date of the shipping of
the material. Warranty is against defects in materials or workmanship when the
product is properly used and maintained in normal efficiency. This Warranty is valid and
enforceable in the country where the product was purchased. In the event that the
product has been purchased in a country of the European Union, the warranty is still
valid in all countries of the Community.
To obtain warranty service, it is requested to comply with the following clauses:
1.
Products must be delivered for repair at the expense of the customer.
2.
The product warranty will be subject to the exhibition of a tax document (receipt,
receipt or bill of sale), which attests to the date of purchase of the product.
3.
The repair will not affect the original date of expiration of the warranty and will
not involve the renewal or extension thereof.
4.
If at the time of the repair, the product has not any defect, it will be charged the
costs of the technical analysis.
5.
The warranty is void if the failure was due to: impacts, falls, misuse or abuse of
the product, use of non-original batteries, accidents, product alteration,
replacement/detachment of seals and/or product tampering. The same also
does not cover damage caused during transport if packages used are unsuitable.
6.
The warranty is not covering the battery of the product.
7.
The warranty does not cover the inability to use the product, other costs
incidental or consequential damages or other expenses incurred by the
purchaser.
8.
The warranty doesn't cover damage to the product caused by usage in any other
way than described in this manual.
Support on the products
If the product needs to be sent to the technical assistance, contact your dealer or
contact the BMETERS After sales service at support@bmeters.com.
Declaration of Conformity
Hereby, B METERS, declares that this MB-PULSE4 is in compliance with the essential
requirements and other relevant provisions of Directive 2004/108/EC.
The complete declaration can be downloaded from the official website
www.bmeters.com.
Contact Info
Tel: +39 0432931415
B METERS Srl
Fax: +39 0432992661
Via Friuli 3
E-Mail (sales/informations):
Gonars (UD) – 33050
E-mail (technical support):
Italy
Web:
www.bmeters.com
info@bmeters.com
support@bmeters.com
v1.0

Advertisement

loading