1. No Power
(1) Symptom
1) Does not minute discharge at module.
2) Non does not come into the front LED.
(2) Procedure check
Is the power cord plugged in?
Is the Line Filter and Power
Board Cable connected?
Is the Fuse(F100) on
Power Board normal?
Is the Power Board and 13P cable
of Main Board Cable connected?
After removing the cables, connect them to the Power Board(except the
SC100 connection cable), and change the AC voltage marking to manual.
When ST-BY 5V does not operate, replace the Power Board.
Yes
Yes
Yes
Yes
No
Plug in the power cord.
No
Connect the Cable.
No
Replace the Fuse.
No
Connect the Cable.
- 18 -